Conveyance
Manning Trapezoidal Swale Calculator
Calculate uniform-flow discharge and Froude number, then check average boundary shear against the lining limit.
Inputs
Swale cross section
Live resultsWithin average lining shear
Subcritical. Compare local bed and bend shear against lining guidance.
Calculation results
- Discharge
- 13.71 cfs
- Velocity
- 2.67 ft/s
- Froude no.
- 0.6
- Avg. shear
- 0.295 lb/ft²
- Hydraulic radius
- 0.59 ft
- Flow area
- 5.13 ft²
- Water surface width
- 8.4 ft
- Wetted perimeter
- 8.69 ft
- Hydraulic depth A/T
- 0.611 ft
- Flow regime
- Subcritical
- Depth-based bed shear
- 0.449 lb/ft²
- Average shear reserve
- 0.905 lb/ft²
Method and assumptions
A = y(b + zy) · R = A/P · Q = K A R²ᐟ³ S¹ᐟ²/n · Fr = V/√(gA/T) · τavg = γRS.
Assumes steady uniform flow and a straight channel. The comparison uses average boundary shear. The depth-based bed shear is shown separately. HEC-15 lining design also evaluates local maximum shear, bends and steep grades.
Worked examples
Manning Trapezoidal Swale Calculator
Inputs
- Bottom width b
- 3 ft
- Side slope z (H:V)
- 3
- Flow depth y
- 0.9 ft
- Longitudinal grade
- 0.8 %
- Manning n
- 0.035
- Permissible shear
- 1.2 lb/ft²
Results
- Discharge
- 13.71 cfs
- Velocity
- 2.67 ft/s
- Froude no.
- 0.6
- Avg. shear
- 0.295 lb/ft²
- Hydraulic radius
- 0.59 ft
- Flow area
- 5.13 ft²
- Water surface width
- 8.4 ft
- Wetted perimeter
- 8.69 ft
- Hydraulic depth A/T
- 0.611 ft
- Flow regime
- Subcritical
- Depth-based bed shear
- 0.449 lb/ft²
- Average shear reserve
- 0.905 lb/ft²
Within average lining shear
Subcritical. Compare local bed and bend shear against lining guidance.
A = y(b + zy) · R = A/P · Q = K A R²ᐟ³ S¹ᐟ²/n · Fr = V/√(gA/T) · τavg = γRS.
Screening worksheet · Verify design using project criteria and site data.