Worked example · Conveyance
36-inch pipe at the full-flow reference
A concrete storm sewer is evaluated at 100% of its diameter and its uniform-flow slope.
Inputs
Circular pipe section
Live resultsVelocity meets the target
Self-cleansing screen at the entered depth and grade.
Calculation results
- Partial flow
- 41.11 cfs
- Full flow
- 41.11 cfs
- Velocity
- 5.82 ft/s
- Q / Q full
- 100 %
- Full-flow velocity
- 5.82 ft/s
- Velocity ratio
- 100 %
- Flow depth
- 3 ft
- Central angle θ
- 6.283 rad
- Wetted area
- 7.07 ft²
- Hydraulic radius
- 0.75 ft
- Wetted perimeter
- 9.42 ft
- Velocity reserve
- 3.32 ft/s
Worked calculation
Observe that Q and V match their full-section references. The result applies to gravity flow at this grade.
θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.
Assumes uniform gravity flow with fixed Manning n and no backwater. At a zero slope the ratios compare section conveyance, while both discharges and velocities are zero. At high part-full depths Q can exceed its full-section reference because hydraulic radius is larger.
More worked examples
Open the main calculator36-inch pipe at the full-flow reference
Inputs
- Inside diameter D
- 36 in
- Depth ratio d/D
- 100 %
- Longitudinal grade
- 0.38 %
- Pipe material
- RCP · n 0.013
- Minimum velocity
- 2.5 ft/s
Results
- Partial flow
- 41.11 cfs
- Full flow
- 41.11 cfs
- Velocity
- 5.82 ft/s
- Q / Q full
- 100 %
- Full-flow velocity
- 5.82 ft/s
- Velocity ratio
- 100 %
- Flow depth
- 3 ft
- Central angle θ
- 6.283 rad
- Wetted area
- 7.07 ft²
- Hydraulic radius
- 0.75 ft
- Wetted perimeter
- 9.42 ft
- Velocity reserve
- 3.32 ft/s
Velocity meets the target
Self-cleansing screen at the entered depth and grade.
θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.
Screening worksheet · Verify design using project criteria and site data.