Worked example · Conveyance

Dry circular storm sewer baseline

A pipe has no water during a dry-weather check. Full-flow capacity remains available as a reference.

Inputs

Pipe section
4–180 in
0–100 %
0–30 %

The full reference uses the same slope and roughness as the partial section.

Roughness and velocity
0.1–15 ft/s

Typical screening targets are 2–3 ft/s (about 0.6–0.9 m/s). Use your agency’s criterion.

Circular pipe section

Live results
Circular pipe section Velocity below the target. Self-cleansing screen at the entered depth and grade. PARTIAL FLOW 0 cfs FULL FLOW 81.11 cfs VELOCITY 0 ft/s Q / Q FULL 0 % Depth d0 ftPipe D42 inInvert 0Velocity target2× target

Velocity below the target

Self-cleansing screen at the entered depth and grade.

Calculation results

Partial flow
0 cfs
Full flow
81.11 cfs
Velocity
0 ft/s
Q / Q full
0 %
Full-flow velocity
8.43 ft/s
Velocity ratio
0 %
Flow depth
0 ft
Central angle θ
0 rad
Wetted area
0 ft²
Hydraulic radius
0 ft
Wetted perimeter
0 ft
Velocity reserve
-2 ft/s

Worked calculation

Start at 0% depth and increase to 5%. The section and ratio remain defined at a dry invert.

θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.

Assumes uniform gravity flow with fixed Manning n and no backwater. At a zero slope the ratios compare section conveyance, while both discharges and velocities are zero. At high part-full depths Q can exceed its full-section reference because hydraulic radius is larger.

Open the main calculator

Share this calculation

This link opens the worksheet with your current inputs and units.