Worked example · Conveyance
Dry circular storm sewer baseline
A pipe has no water during a dry-weather check. Full-flow capacity remains available as a reference.
Inputs
Circular pipe section
Live resultsVelocity below the target
Self-cleansing screen at the entered depth and grade.
Calculation results
- Partial flow
- 0 cfs
- Full flow
- 81.11 cfs
- Velocity
- 0 ft/s
- Q / Q full
- 0 %
- Full-flow velocity
- 8.43 ft/s
- Velocity ratio
- 0 %
- Flow depth
- 0 ft
- Central angle θ
- 0 rad
- Wetted area
- 0 ft²
- Hydraulic radius
- 0 ft
- Wetted perimeter
- 0 ft
- Velocity reserve
- -2 ft/s
Worked calculation
Start at 0% depth and increase to 5%. The section and ratio remain defined at a dry invert.
θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.
Assumes uniform gravity flow with fixed Manning n and no backwater. At a zero slope the ratios compare section conveyance, while both discharges and velocities are zero. At high part-full depths Q can exceed its full-section reference because hydraulic radius is larger.
More worked examples
Open the main calculatorDry circular storm sewer baseline
Inputs
- Inside diameter D
- 42 in
- Depth ratio d/D
- 0 %
- Longitudinal grade
- 0.65 %
- Pipe material
- RCP · n 0.013
- Minimum velocity
- 2 ft/s
Results
- Partial flow
- 0 cfs
- Full flow
- 81.11 cfs
- Velocity
- 0 ft/s
- Q / Q full
- 0 %
- Full-flow velocity
- 8.43 ft/s
- Velocity ratio
- 0 %
- Flow depth
- 0 ft
- Central angle θ
- 0 rad
- Wetted area
- 0 ft²
- Hydraulic radius
- 0 ft
- Wetted perimeter
- 0 ft
- Velocity reserve
- -2 ft/s
Velocity below the target
Self-cleansing screen at the entered depth and grade.
θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.
Screening worksheet · Verify design using project criteria and site data.