Worked example · Conveyance

18-inch concrete storm sewer at half depth

A small reinforced concrete pipe operates with its water surface at the centerline.

Inputs

Pipe section
4–180 in
0–100 %
0–30 %

The full reference uses the same slope and roughness as the partial section.

Roughness and velocity
0.1–15 ft/s

Typical screening targets are 2–3 ft/s (about 0.6–0.9 m/s). Use your agency’s criterion.

Circular pipe section

Live results
Circular pipe section Velocity meets the target. Self-cleansing screen at the entered depth and grade. PARTIAL FLOW 4.52 cfs FULL FLOW 9.04 cfs VELOCITY 5.11 ft/s Q / Q FULL 50 % Depth d0.75 ftPipe D18 inInvert 0Velocity target2× target

Velocity meets the target

Self-cleansing screen at the entered depth and grade.

Calculation results

Partial flow
4.52 cfs
Full flow
9.04 cfs
Velocity
5.11 ft/s
Q / Q full
50 %
Full-flow velocity
5.11 ft/s
Velocity ratio
100 %
Flow depth
0.75 ft
Central angle θ
3.142 rad
Wetted area
0.88 ft²
Hydraulic radius
0.375 ft
Wetted perimeter
2.36 ft
Velocity reserve
2.61 ft/s

Worked calculation

At half depth the wetted hydraulic radius equals the full-pipe radius. Flow is half of Q full while velocity is the same.

θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.

Assumes uniform gravity flow with fixed Manning n and no backwater. At a zero slope the ratios compare section conveyance, while both discharges and velocities are zero. At high part-full depths Q can exceed its full-section reference because hydraulic radius is larger.

Open the main calculator

Share this calculation

This link opens the worksheet with your current inputs and units.