Worked example · Hydrology
Residential street catchment runoff
A short residential block mixes roadway and driveways with lawn and an open verge. Estimate the flow that reaches the low end of the block.
Inputs
Catchment plan
Live resultsComposite runoff estimate
Use rainfall intensity from the local IDF curve at the adopted design duration.
Calculation results
- Peak flow
- 12.69 cfs
- Composite C
- 0.454
- Drainage area
- 7.7 acre
- Kirpich t꜀
- 10.32 min
- US-equivalent flow factor
- 1.00833
Worked calculation
Increase the lawn share while holding total area fixed. The area-weighted C falls and the peak flow changes in the same proportion.
C = Σ(Aᵢ Cᵢ) / ΣAᵢ · Q = C i A × K · t꜀ = 0.0078 L⁰·⁷⁷ S⁻⁰·³⁸⁵ in minutes with L in ft.
The exact US factor is 121/120 and is displayed as 1.0083. SI uses Q = C i A / 360 with i in mm/hr and A in ha. The rounded US convention uses 1.000. Kirpich estimates the channel travel component. Add sheet and shallow concentrated travel where applicable, and verify local minimum durations and area limits.
More worked examples
Open the main calculatorResidential street catchment runoff
Inputs
- Pavement area
- 2.2 acre
- Pavement runoff coefficient
- 0.86
- Landscape area
- 4.1 acre
- Landscape runoff coefficient
- 0.33
- Open ground area
- 1.4 acre
- Open ground runoff coefficient
- 0.18
- Rainfall intensity
- 3.6 in/hr
- US flow conversion
- Exact · 1.0083
- Flow-path length
- 1,240 ft
- Average path grade
- 1.2 %
Results
- Peak flow
- 12.69 cfs
- Composite C
- 0.454
- Drainage area
- 7.7 acre
- Kirpich t꜀
- 10.32 min
- US-equivalent flow factor
- 1.00833
Composite runoff estimate
Use rainfall intensity from the local IDF curve at the adopted design duration.
C = Σ(Aᵢ Cᵢ) / ΣAᵢ · Q = C i A × K · t꜀ = 0.0078 L⁰·⁷⁷ S⁻⁰·³⁸⁵ in minutes with L in ft.
Screening worksheet · Verify design using project criteria and site data.