Conveyance

Manning Trapezoidal Swale Calculator

Calculate uniform-flow discharge and Froude number, then check average boundary shear against the lining limit.

Inputs

Channel section
0–100 ft
0–12
0–30 ft

Use equal side slopes on both banks. A zero bottom width models a V-section.

Slope and lining
0–20 %
0.008–0.2
0.01–50 lb/ft²

Use the permissible shear for the actual lining and installation.

Swale cross section

Live results
Swale cross section Within average lining shear. Subcritical. Compare local bed and bend shear against lining guidance. DISCHARGE 13.71 cfs VELOCITY 2.67 ft/s FROUDE NO. 0.6 AVG. SHEAR 0.295 lb/ft² yb · 3 ftz = 3:1y · 0.9 ft 0Lining limit2× limit

Within average lining shear

Subcritical. Compare local bed and bend shear against lining guidance.

Calculation results

Discharge
13.71 cfs
Velocity
2.67 ft/s
Froude no.
0.6
Avg. shear
0.295 lb/ft²
Hydraulic radius
0.59 ft
Flow area
5.13 ft²
Water surface width
8.4 ft
Wetted perimeter
8.69 ft
Hydraulic depth A/T
0.611 ft
Flow regime
Subcritical
Depth-based bed shear
0.449 lb/ft²
Average shear reserve
0.905 lb/ft²

Method and assumptions

A = y(b + zy) · R = A/P · Q = K A R²ᐟ³ S¹ᐟ²/n · Fr = V/√(gA/T) · τavg = γRS.

Assumes steady uniform flow and a straight channel. The comparison uses average boundary shear. The depth-based bed shear is shown separately. HEC-15 lining design also evaluates local maximum shear, bends and steep grades.

Share this calculation

This link opens the worksheet with your current inputs and units.