Solar Array Row Spacing Calculator

Find the row pitch and clear aisle needed to avoid inter-row shade during a chosen solstice solar-time window.

Inputs

US displays feet and 12-hour times. Metric displays meters and 24-hour times.

North is positive.
Measure the full rack from front lip to rear lip.
Positive means the ground rises toward the backs of the rows.

Inter-row shading cross-section

PV row spacing and shading rayA vertical section through two rows shows the signed ground grade, panel rise, and governing sun ray. 30° TILT0% GRADE2026-12-21PITCH 16.37 ft
Minimum row pitch
16.37 ft
Clear horizontal aisle
10.31 ft
Ground coverage ratio
37%
Governing solar time
3:00 PM
Projected row width
6.06 ft
Panel rise
3.5 ft

Pitch is horizontal, measured from one front edge to the next. Start, end, and governing times are solar time.

Design window
Solstice dateFacingStartEnd
2026-12-21180° S9:00 AM3:00 PM

Project neighboring rows into the same section

Identical parallel rows face the equator. Project the panel stack and solar ray onto the section perpendicular to the row, then increase the horizontal front-edge pitch until the panels stop overlapping along that ray.

The tool checks both endpoints and minute samples between them on the chosen solstice. A beam parallel to the grade can require unbounded spacing. The aisle is the pitch minus the horizontal panel projection. Include equipment access and structural setbacks separately.

Common questions

Do 9 AM and 3 PM mean the times shown on my phone?

The row window uses apparent solar time. Solar noon is 12:00 in that system regardless of longitude, time zone, or daylight saving.

Does ground coverage ratio use the tilted collector length?

This tool uses the horizontal projection of the collector over horizontal pitch. Some PV design tools define GCR with slant length, so check the convention before comparing.

What should I enter for a two-panel rack?

Measure the full sloped depth of one repeating rack from the leading edge to the rear edge, including the gap between modules in the rack.