Canberra, Australia
A June winter PV row layout in Canberra
A landscape installation uses north-facing rows, a 2.25 m slant height, and a gentle fall toward row backs.
Try it. Compare the June and December designs while keeping the window fixed. Use the June result for an initial winter layout.
Inputs used
Inter-row shading cross-section
Results paused. Check the highlighted inputs.
- Minimum row pitch
- 5.04 m
- Clear horizontal aisle
- 3.13 m
- Ground coverage ratio
- 37.8%
- Governing solar time
- 09:00
- Projected row width
- 1.91 m
- Panel rise
- 1.19 m
Pitch is horizontal, measured from one front edge to the next. Start, end, and governing times are solar time.
| Solstice date | Facing | Start | End |
|---|---|---|---|
| 2026-06-21 | 0° N | 09:00 | 15:00 |
Project neighboring rows into the same section
Identical parallel rows face the equator. Project the panel stack and solar ray onto the section perpendicular to the row, then increase the horizontal front-edge pitch until the panels stop overlapping along that ray.
The tool checks both endpoints and minute samples between them on the chosen solstice. A beam parallel to the grade can require unbounded spacing. The aisle is the pitch minus the horizontal panel projection. Include equipment access and structural setbacks separately.
Common questions
Why does Canberra use June for winter spacing?
The local winter solstice is around June 21. Canberra’s summer solstice falls in December.
Is a Canberra north-facing row front edge on the north side?
For an equator-facing tilt here the lower, outward-facing edge is on the north side in the model. Its rear edge is higher and farther south.