Boise, Idaho
Rows climbing a Boise ground-mount site
A ground mount steps up away from the front of each row. The rearward grade is +12%.
Try it. Compare +12%, 0%, and −12%. Check how higher or lower neighboring rows intercept the same solar ray.
Inputs used
Inter-row shading cross-section
Results paused. Check the highlighted inputs.
- Minimum row pitch
- 12.96 ft
- Clear horizontal aisle
- 5.71 ft
- Ground coverage ratio
- 55.9%
- Governing solar time
- 2:30 PM
- Projected row width
- 7.25 ft
- Panel rise
- 3.38 ft
Pitch is horizontal, measured from one front edge to the next. Start, end, and governing times are solar time.
| Solstice date | Facing | Start | End |
|---|---|---|---|
| 2026-12-21 | 180° S | 9:30 AM | 2:30 PM |
Project neighboring rows into the same section
Identical parallel rows face the equator. Project the panel stack and solar ray onto the section perpendicular to the row, then increase the horizontal front-edge pitch until the panels stop overlapping along that ray.
The tool checks both endpoints and minute samples between them on the chosen solstice. A beam parallel to the grade can require unbounded spacing. The aisle is the pitch minus the horizontal panel projection. Include equipment access and structural setbacks separately.
Common questions
How do I decide the sign of the Boise row grade?
Stand at the front edge looking toward the rear of the rack. Ground that rises in that direction has positive grade.
Does the Boise aisle include extra width for maintenance?
The aisle is geometric space between projections. Site-specific equipment access can require more room.