Boise, Idaho

Rows climbing a Boise ground-mount site

A ground mount steps up away from the front of each row. The rearward grade is +12%.

Try it. Compare +12%, 0%, and −12%. Check how higher or lower neighboring rows intercept the same solar ray.

Inputs

US displays feet and 12-hour times. Metric displays meters and 24-hour times.

North is positive.
Measure the full rack from front lip to rear lip.
Positive means the ground rises toward the backs of the rows.

Inter-row shading cross-section

PV row spacing and shading rayA vertical section through two rows shows the signed ground grade, panel rise, and governing sun ray. 25° TILT12% GRADE2026-12-21PITCH 12.96 ft
Minimum row pitch
12.96 ft
Clear horizontal aisle
5.71 ft
Ground coverage ratio
55.9%
Governing solar time
2:30 PM
Projected row width
7.25 ft
Panel rise
3.38 ft

Pitch is horizontal, measured from one front edge to the next. Start, end, and governing times are solar time.

Design window
Solstice dateFacingStartEnd
2026-12-21180° S9:30 AM2:30 PM

Project neighboring rows into the same section

Identical parallel rows face the equator. Project the panel stack and solar ray onto the section perpendicular to the row, then increase the horizontal front-edge pitch until the panels stop overlapping along that ray.

The tool checks both endpoints and minute samples between them on the chosen solstice. A beam parallel to the grade can require unbounded spacing. The aisle is the pitch minus the horizontal panel projection. Include equipment access and structural setbacks separately.

Open array row spacing with the default settings

Common questions

How do I decide the sign of the Boise row grade?

Stand at the front edge looking toward the rear of the rack. Ground that rises in that direction has positive grade.

Does the Boise aisle include extra width for maintenance?

The aisle is geometric space between projections. Site-specific equipment access can require more room.