Buffalo, New York
A winter grazing ray on a Buffalo slope
A designer checks PV rows on a back-falling grade. A winter ray can approach or cross the slope’s angle during the proposed window.
Try it. Narrow the window around noon or test a lower magnitude of downslope. Look for whether the model returns a finite pitch.
Inputs used
Inter-row shading cross-section
Results paused. Check the highlighted inputs.
- Minimum row pitch
- —
- Clear horizontal aisle
- —
- Ground coverage ratio
- —
- Governing solar time
- 9:10 AM
- Projected row width
- 5.96 ft
- Panel rise
- 2.78 ft
The beam becomes parallel to the row-to-row grade. No finite pitch can avoid overlap over this entire window.
| Solstice date | Facing | Start | End |
|---|---|---|---|
| 2026-12-21 | 180° S | 9:00 AM | 3:00 PM |
Project neighboring rows into the same section
Identical parallel rows face the equator. Project the panel stack and solar ray onto the section perpendicular to the row, then increase the horizontal front-edge pitch until the panels stop overlapping along that ray.
The tool checks both endpoints and minute samples between them on the chosen solstice. A beam parallel to the grade can require unbounded spacing. The aisle is the pitch minus the horizontal panel projection. Include equipment access and structural setbacks separately.
Common questions
What does parallel to grade mean for Buffalo’s row pitch?
If the beam runs along the row-to-row grade, separating identical rows on that grade does not separate their projected silhouettes.
Can stepped foundations change Buffalo’s no-finite-pitch result?
Changing the heights of rack bases changes the projection. This case assumes the same mounting arrangement follows one continuous grade.