Worked example · Roof framing
3/12 Gable Roof Area for a 16×20 Building
A 16 ft by 20 ft gable measures 20 ft by 22 ft in plan after overhangs. At 3/12, both planes use the same shallow slope factor.
Example inputs
Worked result
Updates as you type- Common rafter with tail
- 10 ft 2.92 in
- Hip centerline with eave
- 14 ft 4.34 in
- Sloped roof area
- 453.5 ft²
Roof section and birdsmouth
SchematicProject inputs
- Full outside-wall span
- 16 ft
- Rise per 12 of run
- 3
- Building length along ridge
- 20 ft
- Horizontal eave overhang
- 24 in
- Roof plan shape
- Symmetric gable
- Gable overhang per end
- 12 in
- Actual ridge thickness
- 1.5 in
- Sawn rafter stock
- 2 × 8
- Actual wall plate width
- 3.5 in
- Horizontal seat cut
- 3.5 in
Calculation details
- Common rafter with tail
- 10 ft 2.92 in
- Hip centerline with eave
- 14 ft 4.34 in
- Sloped roof area
- 453.5 ft²
- Common run to ridge center
- 8 ft
- Rise from wall line
- 2 ft
- Common length to ridge face
- 8 ft 2.18 in
- Tail length along slope
- 24.74 in
- 45° valley to wall line
- 11 ft 5.87 in
- Common rafter angle
- 14°
- Ridge centerline length
- 22 ft
- Vertical heel cut
- 0.88 in
- Perpendicular birdsmouth depth
- 0.85 in
- Remaining rafter depth
- 6.4 in
Checks and references
- Within limit
Wood bearing seat
R802.6 requires at least 1½ in. of bearing on wood or metal. Seat length must fit the actual plate.
- Within limit
Sawn rafter notch
R802.7.1.1 calls for at least 3½ in. remaining depth and up to 24 in. of cantilever for this detail.
- Reference
Ridge and roof load path
Confirm rafter spans, ties, ridge support, heel connectors and roof loading for the actual assembly.
Worked calculation
The steps use US customary units for the reference formulas.
Lay out the common rafter
Half the span is 96 in. Multiply by 3/12 to get 24 in rise above the wall line.
Allow for the ridge and tail
Subtract half the 1.5 in ridge thickness from run, add 24 in horizontal tail, then multiply by √(1 + slope²) for 10 ft 2.92 in.
Check diagonal framing and area
An equal-pitch 45° hip or valley uses √(2 + slope²) × common run. Multiply the eave-inclusive plan area by the common slope factor for 453.54 ft².
Lay out the birdsmouth
Mark 3.5 in of level seat and 0.88 in of vertical heel. The notch consumes 0.85 in perpendicular to the grain, leaving 6.4 in.
Enter valid values to see the steps for this layout.
Frequently asked questions
How many square feet is the 3/12 roof after including the overhangs?
The 440 ft² roof plan becomes about 453.54 ft² of sloped roof surface.
How are rake overhangs included in this gable area?
Add both end overhangs along the ridge axis before multiplying the eave-inclusive plan width by the slope factor.