Worked example · Roof framing
6/12 Pitch Common Rafter for a 24 ft Span
A symmetric gable spans 24 ft outside to outside of the walls. Use a centered 1½ in. ridge board and set overhang to zero to isolate the common cut length.
Example inputs
Worked result
Updates as you type- Common rafter with tail
- 13 ft 4.16 in
- Hip centerline with eave
- 18 ft
- Sloped roof area
- 858.7 ft²
Roof section and birdsmouth
SchematicProject inputs
- Full outside-wall span
- 24 ft
- Rise per 12 of run
- 6
- Building length along ridge
- 32 ft
- Horizontal eave overhang
- 0 in
- Roof plan shape
- Symmetric gable
- Gable overhang per end
- 0 in
- Actual ridge thickness
- 1.5 in
- Sawn rafter stock
- 2 × 8
- Actual wall plate width
- 3.5 in
- Horizontal seat cut
- 3.5 in
Calculation details
- Common rafter with tail
- 13 ft 4.16 in
- Hip centerline with eave
- 18 ft
- Sloped roof area
- 858.7 ft²
- Common run to ridge center
- 12 ft
- Rise from wall line
- 6 ft
- Common length to ridge face
- 13 ft 4.16 in
- Tail length along slope
- 0 in
- 45° valley to wall line
- 18 ft
- Common rafter angle
- 26.6°
- Ridge centerline length
- 32 ft
- Vertical heel cut
- 1.75 in
- Perpendicular birdsmouth depth
- 1.57 in
- Remaining rafter depth
- 5.68 in
Checks and references
- Within limit
Wood bearing seat
R802.6 requires at least 1½ in. of bearing on wood or metal. Seat length must fit the actual plate.
- Within limit
Sawn rafter notch
For an end notch in sawn lumber, the R502.8.1 screen uses one-quarter of member depth.
- Reference
Ridge and roof load path
Confirm rafter spans, ties, ridge support, heel connectors and roof loading for the actual assembly.
Worked calculation
The steps use US customary units for the reference formulas.
Lay out the common rafter
Half the span is 144 in. Multiply by 6/12 to get 72 in rise above the wall line.
Allow for the ridge and tail
Subtract half the 1.5 in ridge thickness from run, add 0 in horizontal tail, then multiply by √(1 + slope²) for 13 ft 4.16 in.
Check diagonal framing and area
An equal-pitch 45° hip or valley uses √(2 + slope²) × common run. Multiply the eave-inclusive plan area by the common slope factor for 858.65 ft².
Lay out the birdsmouth
Mark 3.5 in of level seat and 1.75 in of vertical heel. The notch consumes 1.57 in perpendicular to the grain, leaving 5.68 in.
Enter valid values to see the steps for this layout.
Frequently asked questions
What rise does a 6/12 pitch create over half a 24 ft span?
The full span halves to 12 ft of run. At 6 in. of rise per foot of run, the roof rises 72 in. to the ridge center.
How much run is removed for a centered 1½ in. ridge board?
Remove half the board thickness, or ¾ in. horizontally. The deduction along the rafter is that run multiplied by the slope factor.