Gas bleed & SCCM conversion / Worked example

Argon Sputter MFC Conversion

A sputter recipe calls for 48 SCCM of argon at a 0 °C reference and 130 L/s effective process speed.

Readout ↓

Inputs

Flow basis and process chamber
°C
L/s

Live readout

Flow converted
Standard flow48SCCMMass flow1.426mg/sChamber load0.09887Pa·m³/sProcess P0.7605PaP₁Gas supplyQMFCP₂Process0.761 PaProcess pressure · Pa vs SCCM00.6271.25039.679.2Reference0 °C / 1 atmP₂ / P₁Known flowCritical ratio—
SCCM
48 SCCM
SLM
0.048 SLM
Torr·L/s
0.608 Torr·L/s
mbar·L/s
0.8106 mbar·L/s
Pa·m³/s
0.08106 Pa·m³/s
mol/s
3.569e-5 mol/s
mg/s
1.426 mg/s
Throughput at chamber temperature
0.09887 Pa·m³/s
Predicted process pressure
0.7605 Pa
Downstream / upstream ratio
Known flow mode
Critical pressure ratio
Known flow mode
Orifice upstream Kn
Known flow mode

    Reading this example

    Compare operating chamber throughput with the standard-flow conversions. The temperature basis changes the conversion to mol/s.

    Model & assumptions

    Reference flow

    ṅ = PₛV̇ₛ/(RTₛ) · Q = ṅRT · ṁ = ṅM

    SCCM and SLM use the selected reference at 101,325 Pa. Throughput conversions in the unit table use the reference temperature. Process pressure uses the separately entered chamber temperature.

    Orifice choking

    r* = (2/(γ+1))^(γ/(γ−1)) · r = P₂/P₁

    Isentropic mass flow follows the subsonic pressure-ratio equation until the flow becomes sonic. Below the critical ratio the model holds mass flow at its choked value. Process pressure is chamber throughput divided by effective speed.