Gas bleed & SCCM conversion / Worked example
Helium Flow at a 20 °C Reference
A helium MFC reports 16 SCCM on a 20 °C, 1 atm basis. Convert it to gas throughput and mass flow.
Inputs
Live readout
Flow converted- SCCM
- 16 SCCM
- SLM
- 0.016 SLM
- Torr·L/s
- 0.2027 Torr·L/s
- mbar·L/s
- 0.2702 mbar·L/s
- Pa·m³/s
- 0.02702 Pa·m³/s
- mol/s
- 1.109e-5 mol/s
- mg/s
- 0.04437 mg/s
- Throughput at chamber temperature
- 0.02702 Pa·m³/s
- Predicted process pressure
- 1.801 Pa
- Downstream / upstream ratio
- Known flow mode
- Critical pressure ratio
- Known flow mode
- Orifice upstream Kn
- Known flow mode
Reading this example
A different standard temperature gives a different molar flow for the same displayed SCCM. Match the basis on the flow certificate.
Model & assumptions
Reference flow
ṅ = PₛV̇ₛ/(RTₛ) · Q = ṅRT · ṁ = ṅM
SCCM and SLM use the selected reference at 101,325 Pa. Throughput conversions in the unit table use the reference temperature. Process pressure uses the separately entered chamber temperature.
Orifice choking
r* = (2/(γ+1))^(γ/(γ−1)) · r = P₂/P₁
Isentropic mass flow follows the subsonic pressure-ratio equation until the flow becomes sonic. Below the critical ratio the model holds mass flow at its choked value. Process pressure is chamber throughput divided by effective speed.