Gas bleed & SCCM conversion / Worked example

Subsonic Argon Bleed

An argon test fixture feeds at 160 kPa absolute and discharges into a 110 kPa backfilled vessel.

Readout ↓

Inputs

Flow basis and process chamber
°C
L/s
Orifice and upstream gas
Pa
Pa
°C
mm
Enter a value above 0 and at most 1.

Live readout

Subsonic flow
Standard flow197.7SCCMMass flow5.872mg/sChamber load0.3583Pa·m³/sProcess P14.93PaP₁Gas supplyQOrifice0.15 mmP₂Process14.9 PaProcess pressure · Pa vs SCCM012.324.60163326Reference0 °C / 1 atmP₂ / P₁0.688Critical ratio0.487
SCCM
197.7 SCCM
SLM
0.1977 SLM
Torr·L/s
2.504 Torr·L/s
mbar·L/s
3.339 mbar·L/s
Pa·m³/s
0.3339 Pa·m³/s
mol/s
1.47e-4 mol/s
mg/s
5.872 mg/s
Throughput at chamber temperature
0.3583 Pa·m³/s
Predicted process pressure
14.93 Pa
Downstream / upstream ratio
0.6875
Critical pressure ratio
0.4871
Orifice upstream Kn
3.284e-4

    Reading this example

    This downstream ratio is above the critical threshold. Vary backpressure to watch the mass flow approach the choked plateau.

    Model & assumptions

    Reference flow

    ṅ = PₛV̇ₛ/(RTₛ) · Q = ṅRT · ṁ = ṅM

    SCCM and SLM use the selected reference at 101,325 Pa. Throughput conversions in the unit table use the reference temperature. Process pressure uses the separately entered chamber temperature.

    Orifice choking

    r* = (2/(γ+1))^(γ/(γ−1)) · r = P₂/P₁

    Isentropic mass flow follows the subsonic pressure-ratio equation until the flow becomes sonic. Below the critical ratio the model holds mass flow at its choked value. Process pressure is chamber throughput divided by effective speed.