Turbo foreline & backing pump / Worked example

Custom Compression From a Turbo Datasheet

A candidate turbo has a specified K₀ of 42,000 for the limiting light gas under the stated conditions.

Readout ↓

Inputs

Backing load and pressure limit
Pa·m³/s
Pa·m³/s
L/s
Pa
%
Compression and foreline gas
mm
°C

Live readout

Backing pressure screen pass
Foreline P13.33PaReserve limit66.3PaInlet floor3.175e-4PaBacking load15.69%PᵢₙChamberK₀TurboPꜰForelineSBackingLog pressure cascadeInlet floor3.17e-4 PaForeline13.3 PaMax backing85 PaReserve limit66.3 PaBacking load15.7%Compression4.2e4
Total foreline throughput
0.056 Pa·m³/s
Estimated foreline pressure
13.33 Pa
Pressure limit with headroom
66.3 Pa
Compression-limited inlet pressure
3.175e-4 Pa
Backing pressure / maximum
15.69%
Process share of total load
80.36%
Foreline Knudsen number
0.02063
Foreline flow regime
Transitional flow

    Reading this example

    Substitute the actual gas-specific compression ratio. The entered foreline pressure is a conservative partial-pressure approximation.

    Model & assumptions

    Foreline balance

    Pfore = (Qproc + Qpurge)/Sback,eff

    The reserve screen sets a lower operating limit than the maximum backing pressure. Input the effective speed at the foreline port and this pressure range.

    Compression floor

    Pin,min = Pfore/K₀

    Compression is species-specific and depends on operating conditions. This screen applies the entered foreline pressure to the selected species as a worst-case partial pressure. Use measured partial pressure where known.