Turbo foreline & backing pump / Worked example
Custom Compression From a Turbo Datasheet
A candidate turbo has a specified K₀ of 42,000 for the limiting light gas under the stated conditions.
Inputs
Compression and foreline gas
Live readout
Backing pressure screen pass- Total foreline throughput
- 0.056 Pa·m³/s
- Estimated foreline pressure
- 13.33 Pa
- Pressure limit with headroom
- 66.3 Pa
- Compression-limited inlet pressure
- 3.175e-4 Pa
- Backing pressure / maximum
- 15.69%
- Process share of total load
- 80.36%
- Foreline Knudsen number
- 0.02063
- Foreline flow regime
- Transitional flow
Reading this example
Substitute the actual gas-specific compression ratio. The entered foreline pressure is a conservative partial-pressure approximation.
Model & assumptions
Foreline balance
Pfore = (Qproc + Qpurge)/Sback,eff
The reserve screen sets a lower operating limit than the maximum backing pressure. Input the effective speed at the foreline port and this pressure range.
Compression floor
Pin,min = Pfore/K₀