Turbo foreline & backing pump / Worked example
Helium Process and Purge Load
A helium process and purge together bring the foreline to 74 Pa. The maximum backing pressure is 90 Pa with a 25% reserve requirement.
Inputs
Compression and foreline gas
Live readout
Backing pressure reserve low- Total foreline throughput
- 0.37 Pa·m³/s
- Estimated foreline pressure
- 74 Pa
- Pressure limit with headroom
- 67.5 Pa
- Compression-limited inlet pressure
- 7.4e-5 Pa
- Backing pressure / maximum
- 82.22%
- Process share of total load
- 86.49%
- Foreline Knudsen number
- 7.284e-3
- Foreline flow regime
- Viscous / continuum
Reading this example
A low reserve can merit a larger backing speed even while the modeled pressure stays below the manufacturer ceiling.
Model & assumptions
Foreline balance
Pfore = (Qproc + Qpurge)/Sback,eff
The reserve screen sets a lower operating limit than the maximum backing pressure. Input the effective speed at the foreline port and this pressure range.
Compression floor
Pin,min = Pfore/K₀
Compression is species-specific and depends on operating conditions. This screen applies the entered foreline pressure to the selected species as a worst-case partial pressure. Use measured partial pressure where known.