Turbo foreline & backing pump / Worked example

Helium Process and Purge Load

A helium process and purge together bring the foreline to 74 Pa. The maximum backing pressure is 90 Pa with a 25% reserve requirement.

Readout ↓

Inputs

Backing load and pressure limit
Pa·m³/s
Pa·m³/s
L/s
Pa
%
Compression and foreline gas
mm
°C

Live readout

Backing pressure reserve low
Foreline P74PaReserve limit67.5PaInlet floor7.4e-5PaBacking load82.22%PᵢₙChamberK₀TurboPꜰForelineSBackingLog pressure cascadeInlet floor7.4e-5 PaForeline74 PaMax backing90 PaReserve limit67.5 PaBacking load82.2%Compression1e6
Total foreline throughput
0.37 Pa·m³/s
Estimated foreline pressure
74 Pa
Pressure limit with headroom
67.5 Pa
Compression-limited inlet pressure
7.4e-5 Pa
Backing pressure / maximum
82.22%
Process share of total load
86.49%
Foreline Knudsen number
7.284e-3
Foreline flow regime
Viscous / continuum

    Reading this example

    A low reserve can merit a larger backing speed even while the modeled pressure stays below the manufacturer ceiling.

    Model & assumptions

    Foreline balance

    Pfore = (Qproc + Qpurge)/Sback,eff

    The reserve screen sets a lower operating limit than the maximum backing pressure. Input the effective speed at the foreline port and this pressure range.

    Compression floor

    Pin,min = Pfore/K₀