Turbo foreline & backing pump / Worked example
Narrow Foreline at Low Throughput
A 3 mm gauge branch sees a low foreline throughput while the backing pump runs at 14 L/s.
Inputs
Compression and foreline gas
Live readout
Backing pressure screen pass- Total foreline throughput
- 2.2e-5 Pa·m³/s
- Estimated foreline pressure
- 1.571e-3 Pa
- Pressure limit with headroom
- 52.5 Pa
- Compression-limited inlet pressure
- 1.571e-9 Pa
- Backing pressure / maximum
- 2.245e-3%
- Process share of total load
- 63.64%
- Foreline Knudsen number
- 2859
- Foreline flow regime
- Molecular flow
Reading this example
Check Kn at the branch diameter. Use pressure-appropriate conductance to obtain effective speed from a nominal pump curve.
Model & assumptions
Foreline balance
Pfore = (Qproc + Qpurge)/Sback,eff
The reserve screen sets a lower operating limit than the maximum backing pressure. Input the effective speed at the foreline port and this pressure range.
Compression floor
Pin,min = Pfore/K₀
Compression is species-specific and depends on operating conditions. This screen applies the entered foreline pressure to the selected species as a worst-case partial pressure. Use measured partial pressure where known.