Mean free path & Knudsen number / Worked example

Argon Sputter Shield Gap

An argon sputter chamber operates at 0.8 Pa with a 26 mm path between target shield and substrate region.

Readout ↓

Inputs

Gas and geometry
Pa
°C
mm
Surface coverage
Enter a probability from 0 to 1.
m⁻²

Live readout

Transitional flow
Mean free path10.86mmKnudsen no.0.4176Thermal speed413.8m/sMonolayer time0.01797sMolecule pathsD 26 mmLog pressure ladder · Torr1e31e01e-41e-81e-11Continuum >33.4 PaOperating P0.8 PaMolecular <0.668 Pa
Mean free path λ
10.86 mm
Knudsen number Kn
0.4176
Gas number density
1.793e20 m⁻³
Mean thermal speed
413.8 m/s
Wall impingement flux
1.855e22 m⁻² s⁻¹
Monolayer time
0.01797 s
Molecular below
0.6682 Pa
Continuum above
33.41 Pa

    Reading this example

    Shield geometry can put the gas in the transitional range at a pressure that would be molecular in a narrower gap.

    Model & assumptions

    Mean free path and regime

    λ = kBT / (√2 πd²P) · Kn = λ/D

    At Kn below 0.01 use continuum screening. Kn from 0.01 through 0.5 is transitional. Above 0.5, use molecular screening. The transition pressures move with gas temperature, species and channel size.

    Wall flux and coverage

    n = P/(kBT) · v̄ = √(8RT/πM) · J = nv̄/4 · τ = Nₛ/(sJ)