Mean free path & Knudsen number / Worked example
Argon Sputter Shield Gap
An argon sputter chamber operates at 0.8 Pa with a 26 mm path between target shield and substrate region.
Inputs
Surface coverage
Live readout
Transitional flow- Mean free path λ
- 10.86 mm
- Knudsen number Kn
- 0.4176
- Gas number density
- 1.793e20 m⁻³
- Mean thermal speed
- 413.8 m/s
- Wall impingement flux
- 1.855e22 m⁻² s⁻¹
- Monolayer time
- 0.01797 s
- Molecular below
- 0.6682 Pa
- Continuum above
- 33.41 Pa
Reading this example
Shield geometry can put the gas in the transitional range at a pressure that would be molecular in a narrower gap.
Model & assumptions
Mean free path and regime
λ = kBT / (√2 πd²P) · Kn = λ/D
At Kn below 0.01 use continuum screening. Kn from 0.01 through 0.5 is transitional. Above 0.5, use molecular screening. The transition pressures move with gas temperature, species and channel size.
Wall flux and coverage
n = P/(kBT) · v̄ = √(8RT/πM) · J = nv̄/4 · τ = Nₛ/(sJ)
The Maxwell–Boltzmann mean speed assumes a thermalized ideal gas. The wall flux counts molecular hits. Multiply by the sticking probability to estimate adsorption on an initially clean surface.