Pipe conductance & pump speed / Worked example

Isolation Valve Sets the Bottleneck

A 100 L/s valve is installed upstream of a 200 L/s turbo. The straight tube is 80 mm ID in molecular flow.

Readout ↓

Inputs

Tube and pump
mm
m
Use zero for a thin aperture in molecular flow.
L/s
Pa
Gas and series restriction
°C
L/s
Enter 0 to omit a valve, baffle or other restriction.

Live readout

Molecular flow
Tube C202.3L/sChamber speed50.14L/sUtilization25.07%ID for 80%No solutionChamberTube + valvePumpID 80 mmChamber speed · L/s vs ID · mm0100200068136FlowMolecularPump speed200 L/s80% target160 L/s
Molecular conductance
202.3 L/s
Laminar conductance model
0.2773 L/s
Molecular transmission
34.78%
Knudsen number Kn
85.47
Regime-adjusted tube conductance
202.3 L/s
Total series conductance
66.92 L/s
Effective chamber speed
50.14 L/s
Pump utilization
25.07%
Minimum inside diameter for 80%
No finite ID in model range

    Reading this example

    Even an unlimited tube cannot give 80% pump speed through this valve. Raise the valve conductance or re-evaluate the utilization target.

    Model & assumptions

    Tube throughput

    Cₘ = (A v̄/4) / (1 + 3L/4D) · Cᵥ = πD⁴P̄/(128ηL)

    The aperture-to-long-tube resistance approximation approaches Clausing’s long-tube limit. It is a simplified short-tube correction. The viscous model assumes isothermal, fully developed laminar flow.

    Chamber speed

    1/Cₜ = 1/C + 1/C₂ · 1/Sₑ = 1/Sₚ + 1/Cₜ

    Transition uses a logarithmic Knudsen weight between the two limits. The 80% search requires Cₜ ≥ 4Sₚ. A fixed series restriction at or below 4Sₚ makes the 80% target unattainable by enlarging the tube alone.