Pipe conductance & pump speed / Worked example
Isolation Valve Sets the Bottleneck
A 100 L/s valve is installed upstream of a 200 L/s turbo. The straight tube is 80 mm ID in molecular flow.
Inputs
Gas and series restriction
Live readout
Molecular flow- Molecular conductance
- 202.3 L/s
- Laminar conductance model
- 0.2773 L/s
- Molecular transmission
- 34.78%
- Knudsen number Kn
- 85.47
- Regime-adjusted tube conductance
- 202.3 L/s
- Total series conductance
- 66.92 L/s
- Effective chamber speed
- 50.14 L/s
- Pump utilization
- 25.07%
- Minimum inside diameter for 80%
- No finite ID in model range
Reading this example
Even an unlimited tube cannot give 80% pump speed through this valve. Raise the valve conductance or re-evaluate the utilization target.
Model & assumptions
Tube throughput
Cₘ = (A v̄/4) / (1 + 3L/4D) · Cᵥ = πD⁴P̄/(128ηL)
The aperture-to-long-tube resistance approximation approaches Clausing’s long-tube limit. It is a simplified short-tube correction. The viscous model assumes isothermal, fully developed laminar flow.
Chamber speed
1/Cₜ = 1/C + 1/C₂ · 1/Sₑ = 1/Sₚ + 1/Cₜ
Transition uses a logarithmic Knudsen weight between the two limits. The 80% search requires Cₜ ≥ 4Sₚ. A fixed series restriction at or below 4Sₚ makes the 80% target unattainable by enlarging the tube alone.