Worked example
Blown Cellulose to R-38 in a Bare Shop Attic
A 600 ft² conditioned shop has a bare attic deck. The crew screens quantities with 25 lb cellulose bags, 1.5 lb/ft³ settled density and a nominal 3.5 R/in.
Try it Try entering the product’s minimum settled depth indirectly through its R per inch and set the specific label coverage. Compare the resulting bags to the density-only estimate.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Added settled depth
- in
- Whole bags
- Material cost
- USD
Bag quantity uses settled depth, modeled density and net bag weight. Compare it with the product label.
Attic insulation section
- Existing insulation R
- R
- Added insulation R
- R
- Final insulation R
- R
- Total settled depth
- in
- Added installed load
- lb/ft²
- Added installed weight
- lb
Inputs used
- Open attic floor area
- 600 ft²
- Existing average depth
- 0 in
- Existing R-value source
- From depth
- Existing material
- Blown fiberglass
- Target insulation R
- R-38
- Material to add
- Blown cellulose
- Cellulose R per thickness
- 3.5 R/in
- Settled cellulose density
- 1.5 lb/ft³
- Net cellulose bag weight
- 25 lb
- Label coverage per bag at the added R
- 0 ft²
- Price per bag or kit
- 15.75 USD
How this calculation works
Subtract the estimated or entered existing R from the target, with a minimum of zero. Divide that difference by R per inch to get added depth. The depth estimate uses 3.5 R/in for existing cellulose, 2.8 for fiberglass and 6.5 for closed-cell foam.
With no label coverage entered, the settled volume times density estimates installed mass. Divide by net bag weight and round up to buy whole bags. Manufacturer maximum coverage at the added R overrides the modeled bag coverage.
For closed-cell spray foam, divide area × depth in board feet by the entered usable kit yield and round up. Material totals exclude equipment, labor, tax and any project waste beyond the entered product yield.
Use the specific product’s settled-depth and coverage instructions when installing, and check air sealing, ventilation paths and equipment clearances before adding insulation.
References
Frequently asked questions
How deep is an R-38 cellulose layer at 3.5 R per inch?
It works out to about 10.86 inches of settled insulation. The manufacturer may specify a different minimum settled depth or an initial installation depth.
Why does the shop case use a density estimate instead of coverage?
It illustrates an early quantity check before a product label is available. Replace the input with manufacturer coverage once the actual bag is selected.