R-30 Estimate for a 70 ft² Bump-Out Using Foam Kits

A builder is pricing a small, accessible bump-out with R-4 already present. The example uses 6.5 R/in closed-cell foam and a usable kit yield of 260 board feet.

Try it Try the nameplate 300 board feet as a separate comparison. The usable yield drives how many kits the same four inches of foam consumes.

Attic area and target
ft²
in
R
Material and package
R/in
lb/ft³
board ft
USD
Added settled depth
4 in
Whole kits
2
Material cost
870 USD

Kit quantity uses the usable cured yield entered above.

Attic insulation section

Existing and added attic insulation depthExisting depth 1 in. Added depth 4 in. Material purchase: 2 kits. Final 30 RExisting 1 inAdded 4 in70 ft² of attic floor
The stack compares existing and added settled depth. The ruler identifies where the added insulation begins.
Existing insulation R
4 R
Added insulation R
26 R
Final insulation R
30 R
Total settled depth
5 in
Added installed load
0.667 lb/ft²
Added installed weight
46.7 lb
Download

How this calculation works

Subtract the estimated or entered existing R from the target, with a minimum of zero. Divide that difference by R per inch to get added depth. The depth estimate uses 3.5 R/in for existing cellulose, 2.8 for fiberglass and 6.5 for closed-cell foam.

With no label coverage entered, the settled volume times density estimates installed mass. Divide by net bag weight and round up to buy whole bags. Manufacturer maximum coverage at the added R overrides the modeled bag coverage.

For closed-cell spray foam, divide area × depth in board feet by the entered usable kit yield and round up. Material totals exclude equipment, labor, tax and any project waste beyond the entered product yield.

Use the specific product’s settled-depth and coverage instructions when installing, and check air sealing, ventilation paths and equipment clearances before adding insulation.

References

Frequently asked questions

Why does the calculator show kits rather than bags for the bump-out?

Spray foam kits are rated by cured volume. A board foot covers one square foot at one inch thick, so 70 ft² by four inches requires 280 board feet before rounding kits.

Can I trust nameplate foam-kit yield for the material order?

Use a realistic usable yield for the substrate and job conditions. Test or documented installed thickness still governs the actual result.