Worked example
R-60 Attic Top-Up with Blown Fiberglass
After air sealing a 1,000 ft² attic, a weatherization crew records R-20 already present. Their fiberglass product covers 32 ft² per bag at the R-40 top-up and costs $33 per bag.
Try it Compare R-60 and R-49 using the correct label coverage for each added R. A coverage value left over from the previous target would misstate the purchase.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Added settled depth
- in
- Whole bags
- Material cost
- USD
Bag quantity uses the entered label coverage at the added R.
Attic insulation section
- Existing insulation R
- R
- Added insulation R
- R
- Final insulation R
- R
- Total settled depth
- in
- Added installed load
- lb/ft²
- Added installed weight
- lb
Inputs used
- Open attic floor area
- 1,000 ft²
- Existing average depth
- 7 in
- Existing R-value source
- Enter known R
- Existing insulation R
- 20 R
- Target insulation R
- R-60
- Material to add
- Blown fiberglass
- Fiberglass R per thickness
- 2.8 R/in
- Settled fiberglass density
- 0.55 lb/ft³
- Net fiberglass bag weight
- 30 lb
- Label coverage per bag at the added R
- 32 ft²
- Price per bag or kit
- 33 USD
How this calculation works
Subtract the estimated or entered existing R from the target, with a minimum of zero. Divide that difference by R per inch to get added depth. The depth estimate uses 3.5 R/in for existing cellulose, 2.8 for fiberglass and 6.5 for closed-cell foam.
With no label coverage entered, the settled volume times density estimates installed mass. Divide by net bag weight and round up to buy whole bags. Manufacturer maximum coverage at the added R overrides the modeled bag coverage.
For closed-cell spray foam, divide area × depth in board feet by the entered usable kit yield and round up. Material totals exclude equipment, labor, tax and any project waste beyond the entered product yield.
Use the specific product’s settled-depth and coverage instructions when installing, and check air sealing, ventilation paths and equipment clearances before adding insulation.
References
Frequently asked questions
Why round fiberglass bags up after entering 32 ft² of coverage?
The job uses 31.25 bags worth of coverage, and suppliers sell full packages. The model rounds up to 32 for purchasing.
How should I handle a separate attic hatch during fiberglass takeoff?
Account for the hatch separately if it uses another product or thickness. Enter the actual loose-fill coverage area for the main attic.