R-60 Attic Top-Up with Blown Fiberglass

After air sealing a 1,000 ft² attic, a weatherization crew records R-20 already present. Their fiberglass product covers 32 ft² per bag at the R-40 top-up and costs $33 per bag.

Try it Compare R-60 and R-49 using the correct label coverage for each added R. A coverage value left over from the previous target would misstate the purchase.

Attic area and target
ft²
in
R
Material and package
R/in
lb/ft³
lb
ft²

Use 0 to estimate bags from settled density. Use the label’s maximum coverage when known.

USD
Added settled depth
14.29 in
Whole bags
32
Material cost
1,056 USD

Bag quantity uses the entered label coverage at the added R.

Attic insulation section

Existing and added attic insulation depthExisting depth 7 in. Added depth 14.29 in. Material purchase: 32 bags. Final 60 RExisting 7 inAdded 14.3 in1,000 ft² of attic floor
The stack compares existing and added settled depth. The ruler identifies where the added insulation begins.
Existing insulation R
20 R
Added insulation R
40 R
Final insulation R
60 R
Total settled depth
21.29 in
Added installed load
0.938 lb/ft²
Added installed weight
937.5 lb
Download

How this calculation works

Subtract the estimated or entered existing R from the target, with a minimum of zero. Divide that difference by R per inch to get added depth. The depth estimate uses 3.5 R/in for existing cellulose, 2.8 for fiberglass and 6.5 for closed-cell foam.

With no label coverage entered, the settled volume times density estimates installed mass. Divide by net bag weight and round up to buy whole bags. Manufacturer maximum coverage at the added R overrides the modeled bag coverage.

For closed-cell spray foam, divide area × depth in board feet by the entered usable kit yield and round up. Material totals exclude equipment, labor, tax and any project waste beyond the entered product yield.

Use the specific product’s settled-depth and coverage instructions when installing, and check air sealing, ventilation paths and equipment clearances before adding insulation.

References

Frequently asked questions

Why round fiberglass bags up after entering 32 ft² of coverage?

The job uses 31.25 bags worth of coverage, and suppliers sell full packages. The model rounds up to 32 for purchasing.

How should I handle a separate attic hatch during fiberglass takeoff?

Account for the hatch separately if it uses another product or thickness. Enter the actual loose-fill coverage area for the main attic.