R-38 Fiberglass Takeoff for the Accessible Attic Area

A steep roof leaves room to top up 750 ft² of an attic interior. The accessible portion starts at R-12, and the chosen fiberglass covers 62 ft² per bag at the added R-26.

Try it Try the whole attic area to see the difference in material use. Return to 750 ft² for the takeoff and evaluate the low eaves as a separate assembly.

Attic area and target
ft²
in
R
Material and package
R/in
lb/ft³
lb
ft²

Use 0 to estimate bags from settled density. Use the label’s maximum coverage when known.

USD
Added settled depth
9.29 in
Whole bags
13
Material cost
364 USD

Bag quantity uses the entered label coverage at the added R.

Attic insulation section

Existing and added attic insulation depthExisting depth 4 in. Added depth 9.29 in. Material purchase: 13 bags. Final 38 RExisting 4 inAdded 9.3 in750 ft² of attic floor
The stack compares existing and added settled depth. The ruler identifies where the added insulation begins.
Existing insulation R
12 R
Added insulation R
26 R
Final insulation R
38 R
Total settled depth
13.29 in
Added installed load
0.484 lb/ft²
Added installed weight
362.9 lb
Download

How this calculation works

Subtract the estimated or entered existing R from the target, with a minimum of zero. Divide that difference by R per inch to get added depth. The depth estimate uses 3.5 R/in for existing cellulose, 2.8 for fiberglass and 6.5 for closed-cell foam.

With no label coverage entered, the settled volume times density estimates installed mass. Divide by net bag weight and round up to buy whole bags. Manufacturer maximum coverage at the added R overrides the modeled bag coverage.

For closed-cell spray foam, divide area × depth in board feet by the entered usable kit yield and round up. Material totals exclude equipment, labor, tax and any project waste beyond the entered product yield.

Use the specific product’s settled-depth and coverage instructions when installing, and check air sealing, ventilation paths and equipment clearances before adding insulation.

References

Frequently asked questions

Why exclude the low eaves from this fiberglass bag count?

This takeoff only covers places where the full added depth can be installed. Treat the restricted areas separately with the correct clearance and insulation strategy.

How can I compare insulation loads for the accessible attic and its eaves?

Run each section with its own area, depth and material. Compare the added weight per area for each location, and use total installed weight when summing the takeoff.