Worked example
R-38 Fiberglass Takeoff for the Accessible Attic Area
A steep roof leaves room to top up 750 ft² of an attic interior. The accessible portion starts at R-12, and the chosen fiberglass covers 62 ft² per bag at the added R-26.
Try it Try the whole attic area to see the difference in material use. Return to 750 ft² for the takeoff and evaluate the low eaves as a separate assembly.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Added settled depth
- in
- Whole bags
- Material cost
- USD
Bag quantity uses the entered label coverage at the added R.
Attic insulation section
- Existing insulation R
- R
- Added insulation R
- R
- Final insulation R
- R
- Total settled depth
- in
- Added installed load
- lb/ft²
- Added installed weight
- lb
Inputs used
- Open attic floor area
- 750 ft²
- Existing average depth
- 4 in
- Existing R-value source
- Enter known R
- Existing insulation R
- 12 R
- Target insulation R
- R-38
- Material to add
- Blown fiberglass
- Fiberglass R per thickness
- 2.8 R/in
- Settled fiberglass density
- 0.55 lb/ft³
- Net fiberglass bag weight
- 30 lb
- Label coverage per bag at the added R
- 62 ft²
- Price per bag or kit
- 28 USD
How this calculation works
Subtract the estimated or entered existing R from the target, with a minimum of zero. Divide that difference by R per inch to get added depth. The depth estimate uses 3.5 R/in for existing cellulose, 2.8 for fiberglass and 6.5 for closed-cell foam.
With no label coverage entered, the settled volume times density estimates installed mass. Divide by net bag weight and round up to buy whole bags. Manufacturer maximum coverage at the added R overrides the modeled bag coverage.
For closed-cell spray foam, divide area × depth in board feet by the entered usable kit yield and round up. Material totals exclude equipment, labor, tax and any project waste beyond the entered product yield.
Use the specific product’s settled-depth and coverage instructions when installing, and check air sealing, ventilation paths and equipment clearances before adding insulation.
References
Frequently asked questions
Why exclude the low eaves from this fiberglass bag count?
This takeoff only covers places where the full added depth can be installed. Treat the restricted areas separately with the correct clearance and insulation strategy.
How can I compare insulation loads for the accessible attic and its eaves?
Run each section with its own area, depth and material. Compare the added weight per area for each location, and use total installed weight when summing the takeoff.