An $850 Triple-Pane Upgrade Premium

A new build already budgets for windows at U-0.30. The U-0.18 option costs $850 extra for twelve 18 ft² units in a 7,100 HDD climate.

Try it Enter the full replacement quote to see the difference, then restore the $850 premium for the actual choice between two new products.

Window assembly
ft²
Btu/(h·ft²·°F)
Btu/(h·ft²·°F)
Climate and costs
°F·days

Use a consistent base, typically 65°F (18.3°C).

°F
$/MMBtu

Enter the price per unit of fuel input energy.

%
USD
Peak heat-loss reduction
2,203 Btu/h
Estimated energy savings / year
117.18 USD
Simple payback
7.3 years

Savings reflect changes in conductive heat loss at the same window area.

Conductive window heat loss

Existing and proposed window heat lossExisting 5,508 Btu/h. Proposed 3,305 Btu/h. 01.5K3K4.5K6KExisting windows5,508 Btu/hU 0.3 Btu/(h·ft²·°F)Proposed windows3,305 Btu/hU 0.18 Btu/(h·ft²·°F)Peak conductive heat loss · Btu/h
The chart compares peak conductive heat loss for the existing and proposed window assemblies at the same temperature difference.
Total window area
216 ft²
Existing peak loss
5,508 Btu/h
Proposed peak loss
3,305 Btu/h
Delivered heat saved / year
4.417 MMBtu
Fuel input saved / year
4.507 MMBtu
Download

How this calculation works

Multiply count by average whole-window area. Conductive design heat loss equals U × area × the design indoor–outdoor temperature difference.

Annual delivered heat savings are the old-to-new difference in UA multiplied by heating degree days and 24 hours per day. Divide by seasonal efficiency to get fuel input saved, then multiply by your marginal energy price.

Simple payback divides incremental installed cost by positive annual dollar savings. This comparison covers conduction only. Solar gain, air leakage, cooling, maintenance and comfort may also affect the project decision.

References

Frequently asked questions

Why use the $850 triple-pane premium instead of the full price?

Both options have a window cost. The decision is whether the incremental outlay buys enough extra energy savings to justify the upgrade.

Do twelve triple-pane windows automatically have the same U-factor?

Ratings vary by window size, operating type, frame and glazing. Split distinctly rated products into separate runs if a representative average is unsuitable.