Worked example
An $850 Triple-Pane Upgrade Premium
A new build already budgets for windows at U-0.30. The U-0.18 option costs $850 extra for twelve 18 ft² units in a 7,100 HDD climate.
Try it Enter the full replacement quote to see the difference, then restore the $850 premium for the actual choice between two new products.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Peak heat-loss reduction
- Btu/h
- Estimated energy savings / year
- USD
- Simple payback
- years
Savings reflect changes in conductive heat loss at the same window area.
Conductive window heat loss
- Total window area
- ft²
- Existing peak loss
- Btu/h
- Proposed peak loss
- Btu/h
- Delivered heat saved / year
- MMBtu
- Fuel input saved / year
- MMBtu
Inputs used
- Window count
- 12
- Average whole-window area
- 18 ft²
- Existing whole-window U-factor
- 0.3 Btu/(h·ft²·°F)
- Proposed whole-window U-factor
- 0.18 Btu/(h·ft²·°F)
- Annual heating degree days
- 7,100 °F·days
- Design indoor–outdoor temperature difference
- 85 °F
- Heating fuel energy price
- 26 $/MMBtu
- Seasonal heating efficiency
- 98 %
- Total incremental installation cost
- 850 USD
How this calculation works
Multiply count by average whole-window area. Conductive design heat loss equals U × area × the design indoor–outdoor temperature difference.
Annual delivered heat savings are the old-to-new difference in UA multiplied by heating degree days and 24 hours per day. Divide by seasonal efficiency to get fuel input saved, then multiply by your marginal energy price.
Simple payback divides incremental installed cost by positive annual dollar savings. This comparison covers conduction only. Solar gain, air leakage, cooling, maintenance and comfort may also affect the project decision.
References
Frequently asked questions
Why use the $850 triple-pane premium instead of the full price?
Both options have a window cost. The decision is whether the incremental outlay buys enough extra energy savings to justify the upgrade.
Do twelve triple-pane windows automatically have the same U-factor?
Ratings vary by window size, operating type, frame and glazing. Split distinctly rated products into separate runs if a representative average is unsuitable.