Window Conduction Savings in an 850 HDD Climate

A home in a mild winter climate has fourteen U-0.45 windows averaging 16 ft². The quote proposes U-0.29 replacements, and the heating comparison uses 850 degree days.

Try it Increase heating degree days to 3,000 and leave design temperature difference fixed. Annual heating savings increase while the peak comparison stays the same.

Window assembly
ft²
Btu/(h·ft²·°F)
Btu/(h·ft²·°F)
Climate and costs
°F·days

Use a consistent base, typically 65°F (18.3°C).

°F
$/MMBtu

Enter the price per unit of fuel input energy.

%
USD
Peak heat-loss reduction
896 Btu/h
Estimated energy savings / year
12.95 USD
Simple payback
540.7 years

Savings reflect changes in conductive heat loss at the same window area.

Conductive window heat loss

Existing and proposed window heat lossExisting 2,520 Btu/h. Proposed 1,624 Btu/h. 07501.5K2.3K3KExisting windows2,520 Btu/hU 0.45 Btu/(h·ft²·°F)Proposed windows1,624 Btu/hU 0.29 Btu/(h·ft²·°F)Peak conductive heat loss · Btu/h
The chart compares peak conductive heat loss for the existing and proposed window assemblies at the same temperature difference.
Total window area
224 ft²
Existing peak loss
2,520 Btu/h
Proposed peak loss
1,624 Btu/h
Delivered heat saved / year
0.731 MMBtu
Fuel input saved / year
0.762 MMBtu
Download

How this calculation works

Multiply count by average whole-window area. Conductive design heat loss equals U × area × the design indoor–outdoor temperature difference.

Annual delivered heat savings are the old-to-new difference in UA multiplied by heating degree days and 24 hours per day. Divide by seasonal efficiency to get fuel input saved, then multiply by your marginal energy price.

Simple payback divides incremental installed cost by positive annual dollar savings. This comparison covers conduction only. Solar gain, air leakage, cooling, maintenance and comfort may also affect the project decision.

References

Frequently asked questions

Why is the annual heating benefit modest in this mild-climate quote?

The 850 heating degree days represent relatively little heating demand. The same reduction in U-factor saves more conductive heat in a colder climate.

What other window rating matters in this warm-climate house?

Solar heat gain coefficient and shading often influence cooling demand. Consider them separately when comparing warm-climate window choices.