Worked example
Low-E Storm Windows for a Twelve-Window House
A retrofit team plans storm panels on twelve wood windows. The estimated combined assembly goes from U-0.55 to U-0.34 in a 4,100 heating-degree-day climate.
Try it Replace the fuel rate with a recent marginal price. The conductive savings stay the same while payback responds to the utility cost.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Peak heat-loss reduction
- Btu/h
- Estimated energy savings / year
- USD
- Simple payback
- years
Savings reflect changes in conductive heat loss at the same window area.
Conductive window heat loss
- Total window area
- ft²
- Existing peak loss
- Btu/h
- Proposed peak loss
- Btu/h
- Delivered heat saved / year
- MMBtu
- Fuel input saved / year
- MMBtu
Inputs used
- Window count
- 12
- Average whole-window area
- 13 ft²
- Existing whole-window U-factor
- 0.55 Btu/(h·ft²·°F)
- Proposed whole-window U-factor
- 0.34 Btu/(h·ft²·°F)
- Annual heating degree days
- 4,100 °F·days
- Design indoor–outdoor temperature difference
- 50 °F
- Heating fuel energy price
- 18 $/MMBtu
- Seasonal heating efficiency
- 88 %
- Total incremental installation cost
- 1,450 USD
How this calculation works
Multiply count by average whole-window area. Conductive design heat loss equals U × area × the design indoor–outdoor temperature difference.
Annual delivered heat savings are the old-to-new difference in UA multiplied by heating degree days and 24 hours per day. Divide by seasonal efficiency to get fuel input saved, then multiply by your marginal energy price.
Simple payback divides incremental installed cost by positive annual dollar savings. This comparison covers conduction only. Solar gain, air leakage, cooling, maintenance and comfort may also affect the project decision.
References
Frequently asked questions
Why use the combined U-factor for a storm-window retrofit?
The storm panel and original sash form one assembly. Use tested or defensible combined ratings for the opening instead of entering the storm panel as a standalone replacement.
Could the storm panels save energy through less air leakage too?
Yes. The degree-day result estimates conduction. Air leakage savings depend on existing sash condition, panel sealing and pressure exposure.