Low-E Storm Windows for a Twelve-Window House

A retrofit team plans storm panels on twelve wood windows. The estimated combined assembly goes from U-0.55 to U-0.34 in a 4,100 heating-degree-day climate.

Try it Replace the fuel rate with a recent marginal price. The conductive savings stay the same while payback responds to the utility cost.

Window assembly
ft²
Btu/(h·ft²·°F)
Btu/(h·ft²·°F)
Climate and costs
°F·days

Use a consistent base, typically 65°F (18.3°C).

°F
$/MMBtu

Enter the price per unit of fuel input energy.

%
USD
Peak heat-loss reduction
1,638 Btu/h
Estimated energy savings / year
65.94 USD
Simple payback
22 years

Savings reflect changes in conductive heat loss at the same window area.

Conductive window heat loss

Existing and proposed window heat lossExisting 4,290 Btu/h. Proposed 2,652 Btu/h. 01.3K2.5K3.8K5KExisting windows4,290 Btu/hU 0.55 Btu/(h·ft²·°F)Proposed windows2,652 Btu/hU 0.34 Btu/(h·ft²·°F)Peak conductive heat loss · Btu/h
The chart compares peak conductive heat loss for the existing and proposed window assemblies at the same temperature difference.
Total window area
156 ft²
Existing peak loss
4,290 Btu/h
Proposed peak loss
2,652 Btu/h
Delivered heat saved / year
3.224 MMBtu
Fuel input saved / year
3.663 MMBtu
Download

How this calculation works

Multiply count by average whole-window area. Conductive design heat loss equals U × area × the design indoor–outdoor temperature difference.

Annual delivered heat savings are the old-to-new difference in UA multiplied by heating degree days and 24 hours per day. Divide by seasonal efficiency to get fuel input saved, then multiply by your marginal energy price.

Simple payback divides incremental installed cost by positive annual dollar savings. This comparison covers conduction only. Solar gain, air leakage, cooling, maintenance and comfort may also affect the project decision.

References

Frequently asked questions

Why use the combined U-factor for a storm-window retrofit?

The storm panel and original sash form one assembly. Use tested or defensible combined ratings for the opening instead of entering the storm panel as a standalone replacement.

Could the storm panels save energy through less air leakage too?

Yes. The degree-day result estimates conduction. Air leakage savings depend on existing sash condition, panel sealing and pressure exposure.