Like-for-Like Window Replacement After Storm Damage

Storm damage forces replacement of five windows. The available replacement has the same U-0.36 rating and opening sizes, and the owner is checking the energy case for paying extra.

Try it Enter U-0.27 and only the additional cost of that model. This turns the spreadsheet-style zero-benefit baseline into a direct upgrade comparison.

Window assembly
ft²
Btu/(h·ft²·°F)
Btu/(h·ft²·°F)
Climate and costs
°F·days

Use a consistent base, typically 65°F (18.3°C).

°F
$/MMBtu

Enter the price per unit of fuel input energy.

%
USD
Peak heat-loss reduction
0 Btu/h
Estimated energy savings / year
0 USD
Simple payback
No positive payback

Savings reflect changes in conductive heat loss at the same window area.

Conductive window heat loss

Existing and proposed window heat lossExisting 1,336 Btu/h. Proposed 1,336 Btu/h. 05001K1.5K2KExisting windows1,336 Btu/hU 0.36 Btu/(h·ft²·°F)Proposed windows1,336 Btu/hU 0.36 Btu/(h·ft²·°F)Peak conductive heat loss · Btu/h
The chart compares peak conductive heat loss for the existing and proposed window assemblies at the same temperature difference.
Total window area
70 ft²
Existing peak loss
1,336 Btu/h
Proposed peak loss
1,336 Btu/h
Delivered heat saved / year
0 MMBtu
Fuel input saved / year
0 MMBtu
Download

How this calculation works

Multiply count by average whole-window area. Conductive design heat loss equals U × area × the design indoor–outdoor temperature difference.

Annual delivered heat savings are the old-to-new difference in UA multiplied by heating degree days and 24 hours per day. Divide by seasonal efficiency to get fuel input saved, then multiply by your marginal energy price.

Simple payback divides incremental installed cost by positive annual dollar savings. This comparison covers conduction only. Solar gain, air leakage, cooling, maintenance and comfort may also affect the project decision.

References

Frequently asked questions

Why does the like-for-like repair have no energy payback?

The U-factor and area are the same, so modeled conductive savings are zero. Repair may still be needed for weather protection and function.

Can a like-for-like replacement make a drafty room feel better?

A better seal around a replacement can reduce drafts even if the product U-factor stays the same. The modeled conductive comparison leaves air leakage out.