Worked example
Like-for-Like Window Replacement After Storm Damage
Storm damage forces replacement of five windows. The available replacement has the same U-0.36 rating and opening sizes, and the owner is checking the energy case for paying extra.
Try it Enter U-0.27 and only the additional cost of that model. This turns the spreadsheet-style zero-benefit baseline into a direct upgrade comparison.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Peak heat-loss reduction
- Btu/h
- Estimated energy savings / year
- USD
- Simple payback
Savings reflect changes in conductive heat loss at the same window area.
Conductive window heat loss
- Total window area
- ft²
- Existing peak loss
- Btu/h
- Proposed peak loss
- Btu/h
- Delivered heat saved / year
- MMBtu
- Fuel input saved / year
- MMBtu
Inputs used
- Window count
- 5
- Average whole-window area
- 14 ft²
- Existing whole-window U-factor
- 0.36 Btu/(h·ft²·°F)
- Proposed whole-window U-factor
- 0.36 Btu/(h·ft²·°F)
- Annual heating degree days
- 3,500 °F·days
- Design indoor–outdoor temperature difference
- 53 °F
- Heating fuel energy price
- 15 $/MMBtu
- Seasonal heating efficiency
- 90 %
- Total incremental installation cost
- 350 USD
How this calculation works
Multiply count by average whole-window area. Conductive design heat loss equals U × area × the design indoor–outdoor temperature difference.
Annual delivered heat savings are the old-to-new difference in UA multiplied by heating degree days and 24 hours per day. Divide by seasonal efficiency to get fuel input saved, then multiply by your marginal energy price.
Simple payback divides incremental installed cost by positive annual dollar savings. This comparison covers conduction only. Solar gain, air leakage, cooling, maintenance and comfort may also affect the project decision.
References
Frequently asked questions
Why does the like-for-like repair have no energy payback?
The U-factor and area are the same, so modeled conductive savings are zero. Repair may still be needed for weather protection and function.
Can a like-for-like replacement make a drafty room feel better?