WaterTreatLab

Ion exchange

Ion-Exchange Softener Resin, Hardness & Salt

Convert hardness to grains, estimate sodium-cycle resin volume and calculate gallons, days and salt between regenerations.

Inputs

Water & resin
gal/d
gpm
gpg
ft³
%
Run length & metals
d
d
mg/L
gpg per mg/L
mg/L
gpg per mg/L

Results

US customary
Run length
1.8053 d
Treated per cycle
32,496 gal
Salt per cycle
240 lb
Peak service loading
3.125 gpm/ft³ 25.065 BV/h
Sodium-cycle resin vesselLive diagram
Sodium-cycle resin vesselCapacity remaining after the entered time in service. Hard feedAdjusted hardness16.95 gpgPeak resin loading3.125 gpm/ft³Softened outletUsable capacity remaining58.456 %ExhaustedRegenerated
Capacity remaining after the entered time in service.
Adjusted hardness
16.95 gpg
Daily hardness load
305,100 grains/d
Usable capacity
550,800 grains
Rated capacity per resin volume
27,000 grains/ft³
Salt per 30 days
3,988.2 lb/30 d
Resin for target interval
26.588 ft³
Usable capacity remaining
58.456 %

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked examples

Equations & conventions

Compensated hardness
H = Hᵣₐw + kꜰₑ[Fe] + kₘₙ[Mn]

US hardness uses gpg, where 1 gpg is approximately 17.118 mg/L as CaCO₃. The editable default Fe/Mn allowances are planning inputs. Use the resin supplier’s corrections.

Usable capacity
C = Vᵣₑₛᵢₙ × Cᵣₐₜₑ𝒹 × (1 − reserve)

The planning curve uses 20,000, 27,000 and 30,000 grains/ft³ at 6, 10 and 15 lb salt/ft³. Capacity and leakage vary by resin and regeneration conditions.

Run length and resin volume
Vcycle = C / H, t = Vcycle / Qday

Daily hardness load is Qday × H. For resin at a target interval, multiply that load by the days and divide by usable capacity per unit resin.

Salt and service loading
Salt/regeneration = Vᵣₑₛᵢₙ × salt rate

Divide salt per regeneration by the run length and multiply by 30 for average 30-day consumption. Peak service flow divided by resin volume gives gpm/ft³ or bed volumes per hour.

Planning basis

The 1–5 gpm/ft³ service range is a C100 bulletin reference. Capacity can change with water chemistry, bed depth, flow and resin condition. Combined Fe/Mn above 0.5 mg/L calls for pretreatment and resin review under conventional waterworks guidance.

Questions

How does a reserve change days between regenerations?

A 15% reserve makes 85% of rated capacity available for the run. This shortens the service interval while salt per regeneration stays the same.

Can I use the hardness result to predict treated iron?

For effluent iron, use resin-specific removal data and samples. The compensation factors model an added exchange load and cannot describe ferric solids or resin fouling.