WaterTreatLab

Membrane separation

RO Recovery, Flux & Concentrate TDS Calculator

Balance an RO train from feed and permeate flow. Check GFD and LMH flux, concentrate TDS and approximate osmotic pressure.

Inputs

Membrane train
gpm
gpm
ft²
Feedwater
mg/L
%
°F

Results

US customary
Recovery
72 %
Permeate flux
14.4 GFD 24.447 LMH
Concentrate TDS
6,359.1 mg/L
Feed osmotic pressure
22.147 psi 1.527 bar
RO pressure vesselLive diagram
RO pressure vesselFlow and dissolved-solids balance across the membrane train. Feed100 gpmPermeate72 gpm18 active elementsConcentrate28 gpmSystem recovery72 %0%75% review100%
Flow and dissolved-solids balance across the membrane train.
Concentration factor
3.5714 ×
Concentrate flow
28 gpm
Permeate TDS
27 mg/L
Concentrate osmotic pressure
78.243 psi 5.3947 bar
Total active area
7,200 ft²
Flux review threshold
18 GFD 30.559 LMH

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked examples

Equations & conventions

Water balance
R = Qₚ / Q𝒻, Q𝒸 = Q𝒻 − Qₚ, CF = Q𝒻 / Q𝒸 = 1 / (1 − R)

Use simultaneous feed and permeate flows at steady state. CF is the ideal concentration factor for completely rejected solute.

Membrane flux
J = 1,440 × Qₚ / (Aₑ × N)

With gpm and ft², J is gal/(ft²·d), or GFD. One GFD is approximately 1.698 LMH. Use the active area in the membrane datasheet.

Salt balance
Cₚ = C𝒻(1 − r), C𝒸 = (Q𝒻C𝒻 − QₚCₚ) / Q𝒸

Enter system rejection as a percentage referenced to feed TDS. The concentrate TDS includes modeled salt passage.

Osmotic pressure
π ≈ 2 × 0.0831446 × Tₖ × C / 58,442.77

This gives bar with C in mg/L and assumes ideal NaCl-equivalent TDS at the entered water temperature. Ion speciation and activity change the real result.

Planning basis

The 75% system-recovery screen and 18/14/12 GFD well/surface/reuse screens are preliminary review triggers. DuPont Table 22 varies by pretreatment and feed SDI and lists separate element-level limits. AWWA M46 and the selected membrane projection provide design context.

Questions

Why can concentrate TDS differ from feed TDS times the concentration factor?

CF assumes complete rejection. Permeate carries salt at lower rejection, so the salt balance predicts a lower concentrate TDS.

Can osmotic pressure size the RO feed pump?

Use a membrane projection for operating pressure. The estimate here describes the solution’s osmotic pressure. A pressure projection also needs membrane permeability, permeate backpressure and channel losses.