WaterTreatLab

Disinfection

UV Dose, UVT & Quartz-Sleeve Lamp Sizing

Explore annular UV attenuation, exposure, derated intensity and lamp power. Derive RED from applicable biodosimetry data.

Inputs

Reactor & water
gpm
gal
%
cm
cm
mJ/cm²
Lamp & quartz sleeve
mW/cm²
%
%
W
Biodosimetry (optional)
Both zero leaves RED blank
log/(mJ/cm²)

Results

US customary
Modeled UV dose
37.316 mJ/cm²
Mean exposure
4.8 s
Lamps for model target
5
Power for model target
1.625 kW
Annular UV intensityLive diagram
Annular UV intensityRadial intensity drops with distance from the quartz sleeve. Annular cross-sectionRelative intensityUVT 88 %10Sleeve3 cmNew lampDerated37.316 mJ/cm²
Radial intensity drops with distance from the quartz sleeve.
Review the operating point
  • The modeled dose is below the entered planning target. Select a validated reactor for the required operating envelope.
Biodosimetry RED
Requires test data
Derated annular mean
7.7742 mW/cm²
Absorption coefficient
0.12783 cm⁻¹
Sleeve × EOLL factor
72 %
Water-gap transmission
68.147 %
Installed lamp power
1.3 kW

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked examples

Equations & conventions

Water attenuation
α = −ln(UVT/100) / 1 cm, I(x)/I₀ = r₀/(r₀+x) × e^(−αx)

Use UVT at 254 nm over a 1 cm cell. The model assumes a cylindrical lamp, uniform water and a representative annular gap.

Annular mean and exposure
Ī = I₀ × [2r₀/(2r₀+L)] × [1−e^(−αL)]/(αL) × sleeve × EOLL × N

The absorption term tends to one at 100% UVT. Exposure is illuminated volume divided by flow, in seconds. Modeled dose is Ī × exposure in mJ/cm².

Planning lamp count
Nneeded = ceil(target / dose per lamp), kW = Nneeded × W / 1,000

The model holds hydraulic exposure and the independent contribution per lamp fixed. Use clean, new-lamp sleeve-interface intensity before the entered fouling and aging factors.

Reduction equivalent dose
RED = observed log inactivation / calibrated bench slope

Optional test inputs require a measured reactor challenge result and a log-linear bench curve through the origin over that response range. Use the validated envelope and validation factors for regulatory credit.

Planning basis

The optical estimate assumes uniform axial flow and independent lamp contributions. Short circuiting, lamp arrangement, sensor response and the dose distribution require manufacturer validation. EPA RED comes from biodosimetry.

Questions

Why do UVT and sleeve fouling have separate controls?

UVT describes absorption along a water path. Sleeve transmission describes losses across the fouled quartz interface. Lamp aging changes the source output.

What is needed to report RED from a UV reactor?

Use a full-scale challenge result and the matching bench dose-response curve. The optional RED calculation applies to a through-origin log-linear calibration over the measured response.