WeibullMTBFLab · Engineering calculation
Wind turbine module early-failure pattern
A recently revised turbine module has an illustrative Weibull shape of 0.78. Compare routine replacement with continuing to operate surviving units.
Run-to-failure optimal (preventive replacement counterproductive)
Inputs
- Weibull shape β
- 0.78
- Characteristic life η
- 54,000 h
- Planned replacement cost Cₚ
- 1,200 cost units
- Failure replacement cost C𝒻
- 9,000 cost units
Results
- Optimal age
- ∞ h
- Optimal rate
- 0.1443858 /h
- Run-to-fail
- 0.1443858 /h
- Cost savings
- 0 %
- Weibull mean life
- 62,333.02 h
- Planned replacement cost
- 1,200 cost units
- Failure replacement cost
- 9,000 cost units
E[cycle time] = ∫₀ᵀ exp[−(u/η)ᵝ] duIntegrate the reliability curve by composite Gauss–Legendre quadrature.C(T) = [Cₚ R(T) + C𝒻 F(T)] / E[cycle time]Use the run-to-failure limit for the reported policy.Run-to-failure cost rate = C𝒻 / MTTFThe failure-only policy costs 0.1443858 per hour.Savings = 1 − C(T*) / C(∞)The modeled saving is 0%.
Replacement restores the item to as-new condition. Costs must share the same currency and include the relevant labor and outage cost. The model assumes independent lifetimes and no replacement delay.