ASME IX · EN 1011-1
Arc Welding Heat Input & Arc Energy
Compare net heat input or electrical arc energy with a WPS window and estimate wire deposition.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsNet heat window · 0.5 kJ/mm to 1.25 kJ/mm on an efficiency-adjusted basis.
Result details
| Net heat input | 0.886 kJ/mm |
|---|---|
| Electrical arc energy | 1.107 kJ/mm |
| Thermal efficiency | 80 % |
| Arc power | 5.72 kW |
| Energy used for check | 0.886 kJ/mm |
| Solid steel wire feed (mass) | 4.15 kg/h |
| Estimated net wire deposition | 3.82 kg/h |
| Entered window minimum | 0.5 kJ/mm |
| Entered window maximum | 1.25 kJ/mm |
| Distance to nearest bound | 0.364 kJ/mm |
Calculation method
Arc energy = 60P / v · Net heat input = η × 60P / v
Use P in kW and travel v in mm/min for kJ/mm. Electrical power comes from V × I / 1,000 or from measured mean instantaneous V × I during the run. For waveform-controlled welding, use the acquisition method required by the governing procedure.
Planning thermal factors are SAW 1.00, GMAW/FCAW/SMAW 0.80 and GTAW 0.60. Use WPS bounds expressed on the same basis as the selected result. Wire figures use a solid-steel equivalent of 7,850 kg/m³. Tubular wire needs measured linear mass for a production estimate.