WeldMetalLab

ASME IX · EN 1011-1

Waveform-controlled FCAW with sampled power

The recorder reports 7.4 kW as the mean of simultaneous voltage-current samples over the run.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Arc parameters
kW
Enter the instrument’s mean instantaneous power over the weld run.
mm/min
mm
m/min
WPS limits
kJ/mm
kJ/mm

Live weld sheet

Updated from inputs
Arc and weld poolNet heat input 1.269 kJ/mm. Electrical arc energy 1.586 kJ/mm. Thermal efficiency 80 %. Arc power 7.4 kW NET HEAT1.269kJ/mmARC ENERGY1.586kJ/mmTHERMAL EFF.80%ARC POWER7.4kW ARC AND WELD POOL Travel 280 mm/minArc 1.586 kJ/mmFCAW ARC ENERGY WINDOWPASS
Pass · within screen

Arc energy window · 0.9 kJ/mm to 1.65 kJ/mm on an electrical basis.

Result details

Net heat input1.269 kJ/mm
Electrical arc energy1.586 kJ/mm
Thermal efficiency80 %
Arc power7.4 kW
Energy used for check1.586 kJ/mm
Solid steel wire feed (mass)8.71 kg/h
Estimated net wire deposition7.14 kg/h
Entered window minimum0.9 kJ/mm
Entered window maximum1.65 kJ/mm
Distance to nearest bound0.064 kJ/mm

Worked example

Starting inputs

WPS energy basis
Sampled arc energy
Welding process
FCAW
Mean sampled V × I
7.4 kW
Travel speed
280 mm/min
Wire diameter
1.6 mm
Wire feed speed
9.2 m/min
Minimum energy
0.9 kJ/mm

Baseline results

Net heat input
1.269 kJ/mm
Electrical arc energy
1.586 kJ/mm
Thermal efficiency
80 %
Arc power
7.4 kW

With 7.4 kW at 280 mm/min travel, electrical arc energy is 1.586 kJ/mm. The 80 % process factor gives 1.269 kJ/mm of net heat input.

Try it. Use this value directly for electrical energy. Averaging the waveforms independently can produce a different power.

Calculation method

Arc energy = 60P / v · Net heat input = η × 60P / v

Use P in kW and travel v in mm/min for kJ/mm. Electrical power comes from V × I / 1,000 or from measured mean instantaneous V × I during the run. For waveform-controlled welding, use the acquisition method required by the governing procedure.

Planning thermal factors are SAW 1.00, GMAW/FCAW/SMAW 0.80 and GTAW 0.60. Use WPS bounds expressed on the same basis as the selected result. Wire figures use a solid-steel equivalent of 7,850 kg/m³. Tubular wire needs measured linear mass for a production estimate.

References

More worked examples