ASME IX · EN 1011-1
Waveform-controlled FCAW with sampled power
The recorder reports 7.4 kW as the mean of simultaneous voltage-current samples over the run.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsArc energy window · 0.9 kJ/mm to 1.65 kJ/mm on an electrical basis.
Result details
| Net heat input | 1.269 kJ/mm |
|---|---|
| Electrical arc energy | 1.586 kJ/mm |
| Thermal efficiency | 80 % |
| Arc power | 7.4 kW |
| Energy used for check | 1.586 kJ/mm |
| Solid steel wire feed (mass) | 8.71 kg/h |
| Estimated net wire deposition | 7.14 kg/h |
| Entered window minimum | 0.9 kJ/mm |
| Entered window maximum | 1.65 kJ/mm |
| Distance to nearest bound | 0.064 kJ/mm |
Worked example
Starting inputs
- WPS energy basis
- Sampled arc energy
- Welding process
- FCAW
- Mean sampled V × I
- 7.4 kW
- Travel speed
- 280 mm/min
- Wire diameter
- 1.6 mm
- Wire feed speed
- 9.2 m/min
- Minimum energy
- 0.9 kJ/mm
Baseline results
- Net heat input
- 1.269 kJ/mm
- Electrical arc energy
- 1.586 kJ/mm
- Thermal efficiency
- 80 %
- Arc power
- 7.4 kW
With 7.4 kW at 280 mm/min travel, electrical arc energy is 1.586 kJ/mm. The 80 % process factor gives 1.269 kJ/mm of net heat input.
Try it. Use this value directly for electrical energy. Averaging the waveforms independently can produce a different power.
Calculation method
Arc energy = 60P / v · Net heat input = η × 60P / v
Use P in kW and travel v in mm/min for kJ/mm. Electrical power comes from V × I / 1,000 or from measured mean instantaneous V × I during the run. For waveform-controlled welding, use the acquisition method required by the governing procedure.
Planning thermal factors are SAW 1.00, GMAW/FCAW/SMAW 0.80 and GTAW 0.60. Use WPS bounds expressed on the same basis as the selected result. Wire figures use a solid-steel equivalent of 7,850 kg/m³. Tubular wire needs measured linear mass for a production estimate.