WeldMetalLab

AWS D1.1 · EN 1011-2

Carbon Equivalent & Steel Preheat

Compute CE(IIW), Pcm and CEN from a mill sheet and screen starting and interpass temperatures.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Mill chemistry · mass %
%
%
%
%
%
%
%
%
%
%
Preheat conditions
mm
Record the combined heat path for fit-up review. Method B uses governing plate thickness below.
mm
kJ/mm
%
Enter zero if unknown.
MPa
°C
°C

Live weld sheet

Updated from inputs
Preheated plate sectionIIW carbon equivalent 0.436 %. Ito–Bessyo Pcm 0.258 %. Yurioka CEN 0.427 %. Preheat screening minimum 95.9 °C CE(IIW)0.436%PCM0.258%CEN0.427%PREHEAT MIN95.9°C PREHEATED PLATE SECTION HAZH8 · diffusible HPlate 25 mmH8 PREHEAT FLOORPASS
Pass · within screen

Preheat floor · 110 °C working temperature vs 95.9 °C minimum.

Result details

IIW carbon equivalent0.436 %
Ito–Bessyo Pcm0.258 %
Yurioka CEN0.427 %
Preheat screening minimum95.9 °C
Base-metal CET0.31 %
Controlling CET0.31 %
Diffusible hydrogen input8 mL/100 g
IIW weldability bandElevated
Combined heat-path input50 mm
Raw Method B estimate95.9 °C
Minimum interpass screen95.9 °C
Working temperature margin14.1 °C

Calculation method

Tₚ = 697·CET + 160·tanh(d/35) + 62·HD⁰·³⁵ + (53·CET − 32)·Q − 328

CE(IIW) = C + Mn/6 + (Cr + Mo + V)/5 + (Ni + Cu)/15. Pcm = C + Si/30 + (Mn + Cu + Cr)/20 + Ni/60 + Mo/15 + V/10 + 5B. CEN = C + [0.75 + 0.25 tanh(20(C − 0.12))]·[Si/24 + Mn/6 + Cu/15 + Ni/20 + (Cr + Mo + V + Nb)/5 + 5B].

The EN 1011-2 Method B screen uses CET = C + (Mn + Mo)/10 + (Cr + Cu)/20 + Ni/40. When supplied, weld-metal CET plus 0.03 is checked against base-metal CET. Method B uses governing plate thickness, separate from the recorded combined thickness. Published model limits are CET 0.20–0.50, plate 10–90 mm, Q 0.5–4 kJ/mm and yield up to 1,000 MPa.

The preheat and interpass floors are the higher of the model result and the entered WPS minimum. The IIW bands at 0.40 and 0.50 are qualitative. Verify procedure assumptions, grade-specific limits, restraint, acceptable upper interpass temperature and the governing AWS requirements.

References

Worked examples