GMAW · GTAW
Shielding Gas Runtime & Pipe Back Purge
Translate cylinder capacity and torch flow into arc hours, then model pipe purge time against an oxygen target.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsPurge O₂ target · 75.1 ppm predicted vs 100 ppm target.
Result details
| Torch arc-on runtime | 9.33 h |
|---|---|
| Torch gas cost per hour | 9.11 USD/h |
| Planned purge duration | 2.86 min |
| Model oxygen at planned time | 75.1 ppm |
| Usable cylinder free gas | 8.952 m³ |
| Dam air volume | 0.0029 m³ |
| Gas for planned purge | 0.0229 m³ |
| Mixing exchanges to target | 7.7 |
| Modeled time to target | 2.75 min |
| Gas cost per planned purge | 0.22 USD |
| Whole purges per cylinder | 391 |
Calculation method
t = N · V / F · O₂(N) = Cᵢ + (209,000 − Cᵢ)e⁻ᴺ
The pressure estimate expands usable gauge pressure over 101.325 kPa to ambient volume at equal temperature, using a single approximate gas Z factor. Rated free gas uses the usable fraction of gauge pressure. Torch runtime assumes continuous set flow. Start/stop gas, leaks and purge consumption shorten available torch time.
Dam volume is π·ID²·L/4. The well-mixed model assumes fresh gas at the entered oxygen level and continuous vented displacement. The entered oxygen target belongs to your WPS. Use a calibrated oxygen meter at the weld to verify purge quality before and during welding.
Keep the purge chamber vented. Shielding gases can displace breathable oxygen around the work. Follow ventilation and confined-space requirements.