Titanium purge limited by inlet purity
The procedure target is 10 ppm, but the entered supply oxygen is 12 ppm.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsPurge O₂ target · 21.5 ppm predicted vs 10 ppm target.
- The target is at or below the incoming gas oxygen. The mixing model has no finite target time.
Result details
| Torch arc-on runtime | 12.64 h |
|---|---|
| Torch gas cost per hour | 6.72 USD/h |
| Planned purge duration | 6.68 min |
| Model oxygen at planned time | 21.5 ppm |
| Usable cylinder free gas | 316.15 ft³ |
| Dam air volume | 0.1336 ft³ |
| Gas for planned purge | 1.3363 ft³ |
| Mixing exchanges to target | — |
| Modeled time to target | — |
| Gas cost per planned purge | 0.36 USD |
| Whole purges per cylinder | 236 |
Worked example
Starting inputs
- Torch flow
- 25.002784 CFH
- Pipe material
- Titanium
- Internal diameter
- 3.5 in
- Dam-to-dam length
- 24 in
- Purge gas flow
- 12 CFH
- Volume exchanges
- 10
- Incoming gas oxygen
- 12 ppm
Baseline results
- Torch arc-on runtime
- 12.64 h
- Torch gas cost per hour
- 6.72 USD/h
- Planned purge duration
- 6.68 min
- Model oxygen at planned time
- 21.5 ppm
10 exchanges of a 0.1336 ft³ chamber at 12 CFH take 6.68 min. The mixed-gas estimate at that point is 21.5 ppm against a 10 ppm target.
Try it. The target has no finite predicted purge time. Increasing the number of exchanges only approaches the inlet concentration.
Calculation method
t = N · V / F · O₂(N) = Cᵢ + (209,000 − Cᵢ)e⁻ᴺ
The pressure estimate expands usable gauge pressure over 101.325 kPa to ambient volume at equal temperature, using a single approximate gas Z factor. Rated free gas uses the usable fraction of gauge pressure. Torch runtime assumes continuous set flow. Start/stop gas, leaks and purge consumption shorten available torch time.
Dam volume is π·ID²·L/4. The well-mixed model assumes fresh gas at the entered oxygen level and continuous vented displacement. The entered oxygen target belongs to your WPS. Use a calibrated oxygen meter at the weld to verify purge quality before and during welding.
Keep the purge chamber vented. Shielding gases can displace breathable oxygen around the work. Follow ventilation and confined-space requirements.