Airport access road JPCP

Size a public highway access road carrying mixed commercial traffic near an airport.

Design readout

Required D
10.67
in
Trial D
11.5
in
Depth margin
0.83
in
Life ratio
1.61
×

Doweled JPCP section

Doweled JPCP sectionJOINT SECTIONLOAD TRANSFERTRANSVERSE JOINTSLABDOWELDTRIAL D11.5 inREQUIRED D10.67 inSUPPORT K220 pci
Section cut across a transverse joint. Dowel dimensions and spacing follow the governing agency detail.

Required thickness met

Marker shows trial thickness relative to the AASHTO thickness requirement.

Calculation ledger
Trial design traffic capacity
15,775,330 ESAL
Trial ESAL margin
5,975,330 ESAL
Serviceability loss ΔPSI
1.6
Reliability deviate Zᵣ
-1.645

Inputs

Changes update results

Design demand
ESAL
Concrete and foundation
psi
ksi
pci
in

Work through this example

  1. Enter traffic, serviceability, concrete properties and effective support.
  2. Solve the rigid design equation on the increasing thickness branch.
  3. Evaluate the trial slab against the required thickness and compute allowable design traffic.

Increase pₜ to 3.0 to tighten the terminal serviceability target.

The life ratio compares AASHTO serviceability-based traffic capacity with design demand. A separate fatigue, erosion or faulting analysis requires project-specific data.

Read the equations and sources