Section cut across a transverse joint. Dowel dimensions and spacing follow the governing agency detail.
Trial slab below target
Marker shows trial thickness relative to the AASHTO thickness requirement.
Calculation ledger
Trial design traffic capacity
2,241,331 ESAL
Trial ESAL margin
-5,658,669 ESAL
Serviceability loss ΔPSI
1.9
Reliability deviate Zᵣ
-1.645
Inputs
Changes update results
Work through this example
Enter traffic, serviceability, concrete properties and effective support.
Solve the rigid design equation on the increasing thickness branch.
Evaluate the trial slab against the required thickness and compute allowable design traffic.
Improve the drainage coefficient without changing k. Both inputs influence the traffic capacity independently.
The life ratio compares AASHTO serviceability-based traffic capacity with design demand. A separate fatigue, erosion or faulting analysis requires project-specific data.
Trial slab below target. Marker shows trial thickness relative to the AASHTO thickness requirement.
Inputs
Design traffic W₁₈
7,900,000 ESAL
Reliability R
95%
Standard error S₀
0.35
Initial serviceability p₀
4.4
Terminal serviceability pₜ
2.5
28-day rupture strength S′c
630 psi
Concrete modulus E꜀
4,200 ksi
Effective support k
55 pci
Load transfer J
3.2
Drainage Cᵈ
0.8
Trial slab D
10 in
Results
Required slab thickness
12.07 in
Trial slab thickness
10 in
Trial thickness margin
-2.07 in
Traffic capacity / demand
0.284×
Trial design traffic capacity
2,241,331 ESAL
Trial ESAL margin
-5,658,669 ESAL
Serviceability loss ΔPSI
1.9
Reliability deviate Zᵣ
-1.645