Section cut across a transverse joint. Dowel dimensions and spacing follow the governing agency detail.
Required thickness met
Marker shows trial thickness relative to the AASHTO thickness requirement.
Calculation ledger
Trial design traffic capacity
1,147,555 ESAL
Trial ESAL margin
347,555 ESAL
Serviceability loss ΔPSI
1.9
Reliability deviate Zᵣ
-0.841
Inputs
Changes update results
Work through this example
Enter traffic, serviceability, concrete properties and effective support.
Solve the rigid design equation on the increasing thickness branch.
Evaluate the trial slab against the required thickness and compute allowable design traffic.
Compare J = 4.1 with J = 3.2 to see the slab thickness effect of better load transfer.
The life ratio compares AASHTO serviceability-based traffic capacity with design demand. A separate fatigue, erosion or faulting analysis requires project-specific data.
Required thickness met. Marker shows trial thickness relative to the AASHTO thickness requirement.
Inputs
Design traffic W₁₈
800,000 ESAL
Reliability R
80%
Standard error S₀
0.35
Initial serviceability p₀
4.4
Terminal serviceability pₜ
2.5
28-day rupture strength S′c
630 psi
Concrete modulus E꜀
4,200 ksi
Effective support k
110 pci
Load transfer J
4.1
Drainage Cᵈ
1
Trial slab D
8 in
Results
Required slab thickness
7.52 in
Trial slab thickness
8 in
Trial thickness margin
0.48 in
Traffic capacity / demand
1.434×
Trial design traffic capacity
1,147,555 ESAL
Trial ESAL margin
347,555 ESAL
Serviceability loss ΔPSI
1.9
Reliability deviate Zᵣ
-0.841
The life ratio compares AASHTO serviceability-based traffic capacity with design demand. A separate fatigue, erosion or faulting analysis requires project-specific data.