Doweled interstate rebuild

Size a doweled slab for a high-ESAL reconstruction with a stronger concrete mix.

Design readout

Required D
12.44
in
Trial D
13
in
Depth margin
0.56
in
Life ratio
1.335
×

Doweled JPCP section

Doweled JPCP sectionJOINT SECTIONLOAD TRANSFERTRANSVERSE JOINTSLABDOWELDTRIAL D13 inREQUIRED D12.44 inSUPPORT K185 pci
Section cut across a transverse joint. Dowel dimensions and spacing follow the governing agency detail.

Required thickness met

Marker shows trial thickness relative to the AASHTO thickness requirement.

Calculation ledger
Trial design traffic capacity
56,073,685 ESAL
Trial ESAL margin
14,073,685 ESAL
Serviceability loss ΔPSI
1.9
Reliability deviate Zᵣ
-1.645

Inputs

Changes update results

Design demand
ESAL
Concrete and foundation
psi
ksi
pci
in

Work through this example

  1. Enter traffic, serviceability, concrete properties and effective support.
  2. Solve the rigid design equation on the increasing thickness branch.
  3. Evaluate the trial slab against the required thickness and compute allowable design traffic.

Reduce the trial slab by 1 in and compare the traffic capacity ratio.

The life ratio compares AASHTO serviceability-based traffic capacity with design demand. A separate fatigue, erosion or faulting analysis requires project-specific data.

Read the equations and sources