Section cut across a transverse joint. Dowel dimensions and spacing follow the governing agency detail.
Required thickness met
Marker shows trial thickness relative to the AASHTO thickness requirement.
Calculation ledger
Trial design traffic capacity
56,073,685 ESAL
Trial ESAL margin
14,073,685 ESAL
Serviceability loss ΔPSI
1.9
Reliability deviate Zᵣ
-1.645
Inputs
Changes update results
Work through this example
Enter traffic, serviceability, concrete properties and effective support.
Solve the rigid design equation on the increasing thickness branch.
Evaluate the trial slab against the required thickness and compute allowable design traffic.
Reduce the trial slab by 1 in and compare the traffic capacity ratio.
The life ratio compares AASHTO serviceability-based traffic capacity with design demand. A separate fatigue, erosion or faulting analysis requires project-specific data.
Required thickness met. Marker shows trial thickness relative to the AASHTO thickness requirement.
Inputs
Design traffic W₁₈
42,000,000 ESAL
Reliability R
95%
Standard error S₀
0.35
Initial serviceability p₀
4.4
Terminal serviceability pₜ
2.5
28-day rupture strength S′c
700 psi
Concrete modulus E꜀
4,600 ksi
Effective support k
185 pci
Load transfer J
3.1
Drainage Cᵈ
1
Trial slab D
13 in
Results
Required slab thickness
12.44 in
Trial slab thickness
13 in
Trial thickness margin
0.56 in
Traffic capacity / demand
1.335×
Trial design traffic capacity
56,073,685 ESAL
Trial ESAL margin
14,073,685 ESAL
Serviceability loss ΔPSI
1.9
Reliability deviate Zᵣ
-1.645