Section cut across a transverse joint. Dowel dimensions and spacing follow the governing agency detail.
Trial slab below target
Marker shows trial thickness relative to the AASHTO thickness requirement.
Calculation ledger
Trial design traffic capacity
10,210,346 ESAL
Trial ESAL margin
-8,689,654 ESAL
Serviceability loss ΔPSI
1.9
Reliability deviate Zᵣ
-1.282
Inputs
Changes update results
Work through this example
Enter traffic, serviceability, concrete properties and effective support.
Solve the rigid design equation on the increasing thickness branch.
Evaluate the trial slab against the required thickness and compute allowable design traffic.
The entered k is illustrative. Vary it separately from the measured concrete properties.
The life ratio compares AASHTO serviceability-based traffic capacity with design demand. A separate fatigue, erosion or faulting analysis requires project-specific data.
Trial slab below target. Marker shows trial thickness relative to the AASHTO thickness requirement.
Inputs
Design traffic W₁₈
18,900,000 ESAL
Reliability R
90%
Standard error S₀
0.45
Initial serviceability p₀
4.4
Terminal serviceability pₜ
2.5
28-day rupture strength S′c
690 psi
Concrete modulus E꜀
4,400 ksi
Effective support k
100 pci
Load transfer J
3.2
Drainage Cᵈ
1
Trial slab D
10.5 in
Results
Required slab thickness
11.53 in
Trial slab thickness
10.5 in
Trial thickness margin
-1.03 in
Traffic capacity / demand
0.54×
Trial design traffic capacity
10,210,346 ESAL
Trial ESAL margin
-8,689,654 ESAL
Serviceability loss ΔPSI
1.9
Reliability deviate Zᵣ
-1.282
The life ratio compares AASHTO serviceability-based traffic capacity with design demand. A separate fatigue, erosion or faulting analysis requires project-specific data.