VSMA-style capacity factors

Vibrating Screen Deck Area & Efficiency Calculator

Estimate vibrating screen area, fines passing efficiency and oversize and undersize streams from feed gradation and deck conditions.

Live results

Screen deck and material split

Edit inputs
Screen deck and material split Four live readings and a schematic of the selected material-handling configuration. Full values follow the diagram. DECK AREA87.46ft²PASS EFF.89.05%UNDERSIZE145.32TPHOVERSIZE94.68TPH VIBRATING DECKMATERIAL SPLITOpening 0.75 inDry deckFeed240 TPHOversize94.68 TPHUndersize145.32 TPHTop deck Required / installed area104.12%Installed deck is below the estimated target area.

Installed deck is below the estimated target area.

All calculated values
Required live deck area
87.459ft²
Estimated passing efficiency
89.047%
Undersize product
145.324TPH
Oversize product
94.676TPH
True undersize in feed
163.2TPH
Undersize retained on deck
17.876TPH
Deck area at 90% recovery
87.459ft²
Aperture base capacity
1.878TPH/ft²
Corrected unit capacity
1.866TPH/ft²
Oversize correction
1.035
Half-size correction
0.96
Deck position correction
1
Wet screening correction
1
Density correction
1

Inputs

Unit system
Operating inputs
TPH
%
%
Percent of total feed smaller than half the selected aperture.
in
lb/ft³
ft²
%
Drive & model factors
TPH/ft²
0 uses the aperture curve. Enter the passing capacity per unit area at the stated reference conditions.

Worked examples

Open and edit any starting case

Equations and assumptions

Aperture rating and corrections

C = C₀ · Fo · Fh · Fd · Fw · Fρ

The default C₀ is 2.2 × aperture(in)^0.55 short tons/h/ft². Reference conditions are 25% oversize, 40% half-size, 100 lb/ft³, top deck, dry screening and 90% recovery. Fo = 1 + 0.5(oversize fraction − 0.25), Fh = 1 + (half-size fraction − 0.40), and Fd = 1/0.9/0.8 by deck position (top/second/third respectively). Wet spray uses Fw = 1 + 0.3/(1 + aperture(in)²). Fρ scales with bulk density. The curve and corrections are illustrative VSMA-style estimates. Use an OEM rating and validate motion, media open area, bed depth and blinding before selection.

Live area and passing efficiency

A₉₀ = Qfeed · fᵤ / C   |   E = 1 − 0.1^(Ainstalled/A₉₀)
Arequired = A₉₀ · ln(1 − Etarget) / ln(0.1)

fᵤ is the fraction smaller than the aperture. This first-pass recovery curve is anchored at 90% for A₉₀. Its estimated recovery depends on the installed live area. Use a sampled and weighed feed and product mass balance to establish plant efficiency.

Stream split

Qpassing = Qfeed · fᵤ · E   |   Qretained = Qfeed − Qpassing

This model assumes coarse particles remain above the aperture. The oversize product includes unrecovered fines. Feed, passing and retained rates use the same mass basis.

References