R = thickness / k • Q = A × (Tambient − Tpayload) / R
Area is measured at the wall mid-plane using interior dimensions plus one wall thickness. This case assumes the cavity follows the payload target. The readout also shows the higher heat leak if the whole cavity approaches the coolant phase temperature.
Coolant consumption
Rate = 3.6 × Q(W) / L(kJ/kg)
Dry ice uses 571 kJ/kg, about 246 BTU/lb, at −78.5 °C. The 0 °C and −21 °C phase-change pack enthalpies are adjustable starting values.
Reserve and qualification
treserve = m / rate × (1 − reserve fraction)
Budget for seams, bridges, air exchange, payload preconditioning, and ambient extremes. Verify the actual pack-out by an instrumented test against its approved qualification protocol and payload limits.
What should I check in the pur dry-ice deep-frozen shipper example?
A colder payload increases conduction even with good insulation. Confirm the effective panel conductivity includes joints and the vented construction.
ColdChainLab · Engineering calculation
PUR dry-ice deep-frozen shipper
Metric SI · https://calcsheetlab.com/coldchainlab/dry-ice-shipper-hold-time/pur-dry-ice-deep-frozen/
Inputs
Interior length
0.48 m
Interior width
0.36 m
Interior height
0.32 m
Insulation thickness
85 mm
Insulation preset
Rigid polyurethane (PUR)
Effective conductivity
0.024 W/(m·K)
Ambient temperature
31 °C
Payload target temperature
-45 °C
Latent-energy reserve
35 %
Coolant
Dry ice (−78.5 °C)
Coolant mass
11 kg
Results
Reserve hold
40.01h
Heat leak
28.35W
Coolant use
0.179kg/h
Nominal hold
61.55h
Mid-wall heat-transfer area
1.32m²
Wall R-value
3.54m²·K/W
Latent energy available
6,281kJ
Phase-change enthalpy
571kJ/kg
Coolant phase temperature
-78.5°C
Hold time set aside
21.54h
Ambient-to-payload difference
76K
Heat leak with cavity at coolant phase temp.
40.84W
Dry ice releases CO₂. Use packaging designed to vent it and follow the applicable handling and shipping requirements.
Use these estimates for preliminary engineering. Verify results against validated cold-chain qualification protocols, applicable ASHRAE Standards 15 and 34, and local food and pharmaceutical regulations. Use manufacturer data, measured operating conditions, and approved acceptance criteria before acting on a result.