ControlLoopLab
Home Step responseWorked example

Overdamped hydraulic actuator

A hydraulic actuator with conservative loop settings is dominated by two different real time constants.

Model inputs

System model
rad/s

Closed-loop step & s-plane poles

Overdamped
Damping ζ
1.8
Overshoot
0%
2% settling
1.8878s
Bandwidth
2.1058rad/s
Second-order step and pole mapStep to unit setpointoutput00.591.181.772.36−0.080.3070.6931.08Time (s)Pole locationsjω (rad/s)−28.2−19.2−10.3−1.347.6−28.2−14.1014.128.2σ (rad/s)Setpoint±2% corridorPoles (×)
T(s) = ωn² / (s² + 2ζωn s + ωn²)

Calculated results

Natural frequency ωn
7rad/s
Damped frequency ωd
0rad/s
Damping ratio ζ
1.8
Peak time
∞s
Overshoot
0%
2% settling time
1.8878s
5% settling time
1.4563s
10–90% rise time
1.0417s
Resonant peak
1×
−3 dB bandwidth
2.1058rad/s
Pole 1 real
−2.1234rad/s
Pole 1 imaginary
0rad/s
Pole 2 real
−23.077rad/s
Pole 2 imaginary
0rad/s

Model and interpretation

Full methodology

Use the matching damping regime

The unity-gain model has conjugate poles for 0 ≤ ζ < 1, a repeated real pole at ζ = 1 and two distinct real poles for ζ > 1. For an underdamped step, overshoot is 100 exp(−πζ/√(1−ζ²)).

Separate first crossing from last crossing

Rise time uses the first 10% and 90% crossings. Settling uses the last exit from each band. An undamped response has no finite settling time. For an extremely large number of oscillations the settling result approaches the exponential envelope at display precision.

Synthesize and recheck

Synthesis uses the standard 4/(ζωn) approximation to target 2% settling. Inspect the exact recalculated settling time and bandwidth before transferring a target to a real controller.