ControlLoopLab
Home Step responseWorked example

Test-rig motion with a 5% overshoot target

A test fixture must track step commands with a gentler transient than a normal positioning move.

Model inputs

System model
%
s

Closed-loop step & s-plane poles

Underdamped
Damping ζ
0.69011
Overshoot
5%
2% settling
1.1378s
Bandwidth
5.3959rad/s
Second-order step and pole mapStep to unit setpointoutput00.3560.7111.071.42−0.0840.3220.7281.13Time (s)Pole locationsjω (rad/s)−4.44−3.01−1.59−0.1671.26−4.65−2.3302.334.65σ (rad/s)Setpoint±2% corridorPoles (×)
T(s) = ωn² / (s² + 2ζωn s + ωn²)

Calculated results

Natural frequency ωn
5.2693rad/s
Damped frequency ωd
3.8134rad/s
Damping ratio ζ
0.69011
Peak time
0.82383s
Overshoot
5%
2% settling time
1.1378s
5% settling time
0.54259s
10–90% rise time
0.39785s
Resonant peak
1.0011×
−3 dB bandwidth
5.3959rad/s
Pole 1 real
−3.6364rad/s
Pole 1 imaginary
3.8134rad/s
Pole 2 real
−3.6364rad/s
Pole 2 imaginary
−3.8134rad/s
Requested 2% design time
1.1s
  • Synthesis uses the 4/(ζωn) time approximation for the target.

Model and interpretation

Full methodology

Use the matching damping regime

The unity-gain model has conjugate poles for 0 ≤ ζ < 1, a repeated real pole at ζ = 1 and two distinct real poles for ζ > 1. For an underdamped step, overshoot is 100 exp(−πζ/√(1−ζ²)).

Separate first crossing from last crossing

Rise time uses the first 10% and 90% crossings. Settling uses the last exit from each band. An undamped response has no finite settling time. For an extremely large number of oscillations the settling result approaches the exponential envelope at display precision.

Synthesize and recheck

Synthesis uses the standard 4/(ζωn) approximation to target 2% settling. Inspect the exact recalculated settling time and bandwidth before transferring a target to a real controller.