ControlLoopLab
Home Step responseWorked example

Servo target with ten percent overshoot

An unloaded servo model is being sized from a motion overshoot target and a starting settling-time requirement.

Model inputs

System model
%
s

Closed-loop step & s-plane poles

Underdamped
Damping ζ
0.59116
Overshoot
10%
2% settling
0.30651s
Bandwidth
22.424rad/s
Second-order step and pole mapStep to unit setpointoutput00.09580.1920.2870.383−0.0880.3370.7631.19Time (s)Pole locationsjω (rad/s)−13.9−9.17−4.40.3675.14−19−9.5109.5119σ (rad/s)Setpoint±2% corridorPoles (×)
T(s) = ωn² / (s² + 2ζωn s + ωn²)

Calculated results

Natural frequency ωn
19.333rad/s
Damped frequency ωd
15.593rad/s
Damping ratio ζ
0.59116
Peak time
0.20148s
Overshoot
10%
2% settling time
0.30651s
5% settling time
0.27142s
10–90% rise time
0.094807s
Resonant peak
1.0487×
−3 dB bandwidth
22.424rad/s
Pole 1 real
−11.429rad/s
Pole 1 imaginary
15.593rad/s
Pole 2 real
−11.429rad/s
Pole 2 imaginary
−15.593rad/s
Requested 2% design time
0.35s
  • Synthesis uses the 4/(ζωn) time approximation for the target.

Model and interpretation

Full methodology

Use the matching damping regime

The unity-gain model has conjugate poles for 0 ≤ ζ < 1, a repeated real pole at ζ = 1 and two distinct real poles for ζ > 1. For an underdamped step, overshoot is 100 exp(−πζ/√(1−ζ²)).

Separate first crossing from last crossing

Rise time uses the first 10% and 90% crossings. Settling uses the last exit from each band. An undamped response has no finite settling time. For an extremely large number of oscillations the settling result approaches the exponential envelope at display precision.

Synthesize and recheck

Synthesis uses the standard 4/(ζωn) approximation to target 2% settling. Inspect the exact recalculated settling time and bandwidth before transferring a target to a real controller.