Undamped spring–mass reference

An ideal spring–mass reference is used to check the difference between resonance and decaying oscillation.

Model inputs

System model
rad/s

Closed-loop step & s-plane poles

Undamped
Damping ζ
0
Overshoot
100%
2% settling
∞s
Bandwidth
34.183rad/s
Second-order step and pole mapStep to unit setpointoutput00.2860.5710.8571.14−0.160.6131.392.16Time (s)Pole locationsjω (rad/s)−26.8−18.3−9.8−1.277.25−26.8−13.4013.426.8σ (rad/s)Setpoint±2% corridorPoles (×)
T(s) = ωn² / (s² + 2ζωn s + ωn²)

Calculated results

Natural frequency ωn
22rad/s
Damped frequency ωd
22rad/s
Damping ratio ζ
0
Peak time
0.1428s
Overshoot
100%
2% settling time
∞s
5% settling time
∞s
10–90% rise time
0.046346s
Resonant peak
∞×
−3 dB bandwidth
34.183rad/s
Pole 1 real
0rad/s
Pole 1 imaginary
22rad/s
Pole 2 real
0rad/s
Pole 2 imaginary
−22rad/s
  • Undamped poles lie on the imaginary axis. Oscillations persist and settling time is unbounded.

Model and interpretation

Full methodology

Use the matching damping regime

The unity-gain model has conjugate poles for 0 ≤ ζ < 1, a repeated real pole at ζ = 1 and two distinct real poles for ζ > 1. For an underdamped step, overshoot is 100 exp(−πζ/√(1−ζ²)).

Separate first crossing from last crossing

Rise time uses the first 10% and 90% crossings. Settling uses the last exit from each band. An undamped response has no finite settling time. For an extremely large number of oscillations the settling result approaches the exponential envelope at display precision.

Synthesize and recheck

Synthesis uses the standard 4/(ζωn) approximation to target 2% settling. Inspect the exact recalculated settling time and bandwidth before transferring a target to a real controller.