ControlLoopLab
Home CalculatorsLoop design

Second-order step response

Evaluate overshoot, settling, bandwidth and pole locations, or synthesize a model from overshoot and settling targets.

Model inputs

System model
rad/s

Closed-loop step & s-plane poles

Underdamped
Damping ζ
0.48
Overshoot
17.926%
2% settling
0.6853s
Bandwidth
15.532rad/s
Second-order step and pole mapStep to unit setpointoutput00.2140.4280.6420.857−0.09430.3620.8181.27Time (s)Pole locationsjω (rad/s)−7.03−4.4−1.780.8443.47−12.8−6.4206.4212.8σ (rad/s)Setpoint±2% corridorPoles (×)
T(s) = ωn² / (s² + 2ζωn s + ωn²)

Calculated results

Natural frequency ωn
12rad/s
Damped frequency ωd
10.527rad/s
Damping ratio ζ
0.48
Peak time
0.29843s
Overshoot
17.926%
2% settling time
0.6853s
5% settling time
0.43965s
10–90% rise time
0.13331s
Resonant peak
1.1874×
−3 dB bandwidth
15.532rad/s
Pole 1 real
−5.76rad/s
Pole 1 imaginary
10.527rad/s
Pole 2 real
−5.76rad/s
Pole 2 imaginary
−10.527rad/s

Model and interpretation

Full methodology

Use the matching damping regime

The unity-gain model has conjugate poles for 0 ≤ ζ < 1, a repeated real pole at ζ = 1 and two distinct real poles for ζ > 1. For an underdamped step, overshoot is 100 exp(−πζ/√(1−ζ²)).

Separate first crossing from last crossing

Rise time uses the first 10% and 90% crossings. Settling uses the last exit from each band. An undamped response has no finite settling time. For an extremely large number of oscillations the settling result approaches the exponential envelope at display precision.

Synthesize and recheck

Synthesis uses the standard 4/(ζωn) approximation to target 2% settling. Inspect the exact recalculated settling time and bandwidth before transferring a target to a real controller.